1. හැඳින්වීම
This manual provides detailed instructions for the installation, operation, and maintenance of the Sloan Regal 186 Exposed Manual Urinal Flushometer, Model 3082675. This flushometer is designed for commercial urinal applications, featuring a 1.0 GPF (Gallons Per Flush) manual flush valve with a non-hold-open handle. It is ADA compliant and constructed with high copper, low zinc brass castings for dezincification resistance, ensuring durability and hygienic operation.
2 ආරක්ෂිත තොරතුරු
Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in property damage or injury.
- කිසියම් ස්ථාපනයක් හෝ නඩත්තුවක් ආරම්භ කිරීමට පෙර ප්රධාන ජල සැපයුම අක්රිය කර ඇති බවට වග බලා ගන්න.
- ආරක්ෂිත කණ්නාඩි සහ අත්වැසුම් වැනි සුදුසු පුද්ගලික ආරක්ෂක උපකරණ (PPE) පළඳින්න.
- All plumbing work should comply with local codes and regulations.
- Do not overtighten connections, as this may damage components.
- If you are unsure about any part of the installation or repair process, consult a qualified plumber.
3. පැකේජ අන්තර්ගතය
ස්ථාපනය ආරම්භ කිරීමට පෙර සියලුම සංරචක පවතින බව තහවුරු කර ගන්න.
- Sloan Regal 186 Exposed Manual Urinal Flushometer (Model 3082675)
- Sweat Solder Adapter
- ආවරණ නළය
- වැකුම් බ්රේකර් ෆ්ලෂ් සම්බන්ධතාවය
- 3/4" I.P.S. Screwdriver Bak-Chek Angle Stop
- පාලන නැවතුම් ප්ලග්
- Set Screw සමඟින් වාත්තු වෝල් ෆ්ලැන්ජ්
- ADA අනුකූල ලෝහ දෝලනය නොවන රඳවා තබා-විවෘත හසුරුව
4. සැකසුම සහ ස්ථාපනය
This section outlines the general steps for installing the flushometer. Refer to detailed plumbing diagrams for specific configurations.
4.1. Prepare Water Supply
- Turn off the main water supply to the fixture.
- Flush the urinal to relieve any remaining water pressure.
- Ensure the water supply pipe is properly sized (typically 1-1/2" X 3/4" X 9" for the sweat kit).
4.2. Install Bak-Chek Angle Stop
- Thread the 3/4" I.P.S. screwdriver Bak-Chek angle stop onto the water supply pipe.
- Use pipe sealant or Teflon tape on threads to ensure a watertight seal.
- ආරක්ෂිතව තද කරන්න, නමුත් අධික ලෙස තද නොකරන්න.
4.3. Mount Wall Flange
- Position the cast wall flange over the angle stop.
- Secure the wall flange to the wall using appropriate fasteners (not included) and the provided set screw.
4.4. Connect Flushometer Body
- Attach the flushometer body to the angle stop.
- Connect the vacuum breaker flush connection to the urinal's top spud.
- සියලුම සම්බන්ධතා තදින් හා නිසි ලෙස මුද්රා තබා ඇති බවට සහතික වන්න.
- Install the sweat solder adapter and cover tube as required for your specific plumbing setup.
4.5. අවසාන චෙක්පත්
- ප්රධාන ජල සැපයුම සෙමින් සක්රිය කරන්න.
- කාන්දුවීම් සඳහා සියලු සම්බන්ධතා පරීක්ෂා කරන්න.
- Adjust the control stop plug to regulate water flow as needed.
5. මෙහෙයුම් උපදෙස්
The Sloan Regal 186 Flushometer features a simple manual operation.
5.1. Flushing the Urinal
- Locate the ADA compliant metal oscillating non-hold-open handle on the flushometer.
- Push the handle down firmly and release. The non-hold-open design ensures a consistent 1.0 GPF flush, promoting water conservation.
- The flushometer will automatically reset after the flush cycle is complete.
6. නඩත්තු කිරීම
Regular maintenance ensures optimal performance and longevity of your flushometer.
6.1 පිරිසිදු කිරීම
- Clean the exterior of the flushometer with a mild, non-abrasive cleaner and a soft cloth.
- Avoid using harsh chemicals or abrasive pads, as these can damage the polished chrome finish.
6.2. Diaphragm and Gasket Inspection
- Periodically inspect the diaphragm and other internal gaskets for wear or damage.
- If leaks or inconsistent flushing occur, these components may need replacement. Refer to Sloan's official service guides for detailed replacement procedures.
6.3. Control Stop Adjustment
- The control stop plug allows for adjustment of water flow. If the flush volume is too low or too high, use a screwdriver to adjust the control stop.
- Turn clockwise to decrease flow, counter-clockwise to increase flow. Adjust incrementally until desired flush is achieved.
7. දෝශ නිරාකරණය
This section addresses common issues you might encounter with your flushometer.
| ගැටලුව | විය හැකි හේතුව | විසඳුම |
|---|---|---|
| Flushometer does not flush | Water supply turned off; Clogged internal components; Handle mechanism issue. | Check water supply valve; Inspect and clean diaphragm/bypass; Check handle assembly for obstructions. |
| Continuous flushing or slow closing | Worn or damaged diaphragm; Debris in bypass hole; Improperly seated components. | Replace diaphragm; Clean bypass hole; Reassemble components correctly. |
| Insufficient flush volume | Control stop not fully open; Low water pressure; Partially clogged inlet. | Adjust control stop to increase flow; Check building water pressure; Inspect and clean inlet screen. |
| සම්බන්ධතා වලින් කාන්දුවීම් | Loose connections; Damaged gaskets/seals; Improperly applied sealant. | Tighten connections; Replace worn gaskets/seals; Reapply pipe sealant correctly. |
If troubleshooting steps do not resolve the issue, contact Sloan customer support or a qualified plumber.
8. පිරිවිතර
| විශේෂාංගය | විස්තර |
|---|---|
| ආදර්ශ අංකය | 3082675 |
| ෆ්ලෂ් පරිමාව | 1.0 GPF (ෆ්ලෂ් එකකට ගැලුම්) |
| අවසන් කරන්න | ඔප දැමූ ක්රෝම් |
| ද්රව්ය | Brass (High copper, low zinc castings) |
| සවි කිරීම් සම්බන්ධතාවය | Top Spud |
| හැසිරවීමේ වර්ගය | Manual, Non-Hold-Open, ADA Compliant Metal Oscillating |
| වැකුම් බ්රේකර් | ඇතුළත් |
| කෝණ නැවතුම | 3/4" I.P.S. Screwdriver Bak-Chek |
| මානයන් (ආසන්න වශයෙන්) | අඟල් 1 x 2 x 3 (නිෂ්පාදන මානයන්) |
| අයිතමයේ බර | රාත්තල් 6 කි |
| සහතික කිරීම | ADA |
9. වගකීම් සහ සහාය
9.1. වගකීම් තොරතුරු
The Sloan Regal 186 Exposed Manual Urinal Flushometer (Model 3082675) comes with a වසර 3ක සීමිත වගකීමක්. This warranty covers defects in materials and workmanship under normal use and service. For full details regarding warranty coverage, limitations, and claims, please refer to the official Sloan warranty documentation or contact Sloan customer support.
9.2. පාරිභෝගික සහාය
For technical assistance, replacement parts, or warranty inquiries, please contact Sloan customer support. Visit the official Sloan webසම්බන්ධතා තොරතුරු සහ අමතර සම්පත් සඳහා අඩවිය.
Note: Always provide your product model number (3082675) when contacting support for faster service.