1. හැඳින්වීම
The APC Back-UPS RS 700 VA Tower UPS (Uninterruptible Power Supply) provides reliable battery backup and surge protection for your electronic devices. Designed to safeguard your equipment from power outages, surges, and spikes, this unit ensures continuous operation and protects against data loss. It features a 700VA/450W capacity, offering approximately 3 minutes of full load runtime.

රූපය 1: ඉදිරිපස view of the APC Back-UPS RS 700 VA Tower UPS. The display shows current load, online status, estimated run time in minutes (e.g., 30 minutes), and AVR (Automatic Voltage Regulation) status. Power and display control buttons are located at the top.
ප්රධාන ලක්ෂණ:
- හරිත මාදිලිය: Patented operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Battery Failure Notification: කාලෝචිත වැළැක්වීමේ නඩත්තුව සක්රීය කරමින් බැටරි පිළිබඳ පූර්ව අනතුරු ඇඟවීමේ දෝෂ විශ්ලේෂණයක් සපයයි.
- Power-Saving Outlets: Automatically cuts power to idle equipment to conserve electricity.
- Resettable Circuit Breaker: අධික බරින් පහසුවෙන් සුවය ලැබීම; ෆියුස් ප්රතිස්ථාපනය කිරීමට අවශ්ය නොවේ.
- Battery-Protected and Surge-Only Outlets: Protects connected equipment from power surges and spikes, while providing battery backup power during outages to critical devices.
- Cold-Start Capable: උපයෝගිතා බලය අවසන් වූ විට තාවකාලික බැටරි බලය සපයයි.
- Hot-Swappable Batteries: බැටරි ප්රතිස්ථාපනය කරන අතරතුර ආරක්ෂිත උපකරණ සඳහා පිරිසිදු, අඛණ්ඩ බලය සහතික කරයි.
- Disconnected Battery Notification: උපස්ථ බලය සැපයීමට බැටරියක් නොමැති විට අනතුරු අඟවයි.
- Dataline Surge Protection: Provides protection of connected equipment from power surges on the data lines.
- ස්වයංක්රීය ස්වයං පරීක්ෂණය: ආවර්තිතා බැටරි ස්වයං-පරීක්ෂණය මඟින් ප්රතිස්ථාපනය කිරීමට අවශ්ය බැටරියක් කල්තියා හඳුනා ගැනීම සහතික කරයි.
- සකස් කළ හැකි වෙළුමtage-Transfer Points: ආදාන පරිමාව පුළුල් කිරීමෙන් ප්රයෝජනවත් බැටරි ආයු කාලය උපරිම කරයිtage window or tightening it to regulate output voltage.
- සකස් කළ හැකි වෙළුමtagසංවේදීතාව: නිශ්චිත බල පරිසරයන් හෝ උත්පාදක යෙදුම්වල ප්රශස්ත කාර්ය සාධනය සඳහා UPS අනුවර්තනය කිරීමේ හැකියාව සපයයි.
- ඇසෙන අනතුරු ඇඟවීම්: Provides notification of changing utility power and UPS power conditions.
- පරිශීලක-ප්රතිස්ථාපනය කළ හැකි බැටරි: Increases availability by allowing a trained user to perform upgrades and replacements of batteries reducing Mean Time to Repair (MTTR).
- USB සම්බන්ධතාවය: Provides management of the UPS via a USB port.
- අනුක්රමික සම්බන්ධතාවය: අනුක්රමික වරායක් හරහා UPS කළමනාකරණය සපයයි.
- Transformer-Block Spaced Outlets: Protects equipment with input transformer blocks without blocking access to other receptacles.
- Boost and Trim Automatic Voltagඊ නියාමනය (AVR): Corrects low and high voltages without using the battery, extending battery life.
- බුද්ධිමත් බැටරි කළමනාකරණය: බුද්ධිමත්, නිරවද්ය ආරෝපණය හරහා බැටරි ක්රියාකාරිත්වය, ආයු කාලය සහ විශ්වසනීයත්වය උපරිම කරයි.
- Safety-Agency Approved: සම්බන්ධිත සේවා සපයන්නාගේ උපකරණ සමඟ සහ නිශ්චිත පරිසරය තුළ ආරක්ෂිතව වැඩ කිරීමට නිෂ්පාදිතය පරීක්ෂා කර අනුමත කර ඇති බව සහතික කරයි.
- ගොඩනැගිලි රැහැන් දෝෂ දර්ශකය: This LED informs users of potentially dangerous wiring problems in the wall circuit.
- Battery Replacement Without Tools: Enables quick, easy battery replacement.
- LCD Graphics Display: Provides clear, concise information with text and mimic diagrams that display modes of operation, system parameters, and alarms.
2. පිහිටුවීම
2.1 ඇසිරීම සහ ස්ථානගත කිරීම
Carefully unpack the UPS and inspect it for any shipping damage. Place the UPS in a location that is clean, dry, and away from direct sunlight or excessive heat. Ensure adequate ventilation around the unit. The tower form factor allows for vertical placement.
2.2 බලයට සම්බන්ධ කිරීම
- Connect the UPS power cord to a grounded 3-prong outlet. The power cord is approximately 5 feet long, providing flexibility for placement.
- සම්පූර්ණ බැටරි ධාරිතාවය සහතික කිරීම සඳහා තීරණාත්මක උපකරණ සම්බන්ධ කිරීමට පෙර අවම වශයෙන් පැය 24ක් UPS ආරෝපණය කිරීමට ඉඩ දෙන්න.
- Observe the Building Wiring Fault Indicator. If this LED illuminates, it indicates a potential wiring problem in the wall circuit that should be addressed by a qualified electrician.
2.3 සම්බන්ධක උපකරණ
The UPS features both battery-protected and surge-only outlets.
- Battery-Protected Outlets (NEMA 5-15R): Connect critical equipment such as computers, monitors, and network devices (modems, routers) to these outlets. These outlets provide power during outages and protection against surges.
- Surge-Only Outlets (NEMA 5-15R): Connect non-critical equipment like printers, scanners, or desk lamps to these outlets. These outlets provide surge protection but do not offer battery backup during a power failure.
2.4 Data Line Protection
Connect your telephone, network, or coaxial cables through the designated ports on the UPS to protect against surges traveling through these lines.
2.5 USB and Serial Connectivity
For advanced management and monitoring, connect the UPS to your computer using the provided USB or serial cable. Install the appropriate power management software (available from APC's website) to configure settings, monitor power conditions, and perform graceful shutdowns.
2.6 බිත්ති සවි කිරීම
The unit can be wall-mounted using the keyhole slots on the back. Ensure the mounting surface is sturdy enough to support the weight of the UPS and that proper fasteners are used.
3. මෙහෙයුම
3.1 බල ගැන්වීම සක්රිය / අක්රිය කිරීම
- To power on the UPS, press the power button located on the front panel.
- To power off the UPS, press and hold the power button until the unit shuts down.
3.2 LCD Graphics Display
The LCD display provides real-time information about the UPS status, including:
- පැටවීමේ මට්ටම: ප්රතිශතය පෙන්නුම් කරයිtagසම්බන්ධිත උපකරණ මගින් භාවිතා කරන UPS ධාරිතාවයෙන් e.
- සබැඳි තත්ත්වය: Shows when the UPS is operating on utility power.
- ඇස්තමේන්තුගත ධාවන කාලය: Displays the approximate remaining battery runtime in minutes during a power outage.
- AVR Status: Indicates when Automatic Voltage Regulation is actively correcting input voltage බැටරි බලය භාවිතා නොකර.
- පද්ධති පරාමිතීන්: Provides details on input/output voltage, frequency, and battery charge level.
- අනතුරු ඇඟවීම්: Notifies of critical events or warnings.
3.3 ස්වයංක්රීය වෙළුමtagඊ නියාමනය (AVR)
The Boost and Trim AVR feature automatically corrects minor voltage fluctuations (sags and surges) in incoming utility power without switching to battery power. This preserves battery life and ensures a stable power supply to your connected devices.
3.4 Power Outage Response
බලයක් අතරතුර ඕtage, the UPS automatically switches to battery power, providing uninterrupted power to devices connected to the battery-protected outlets. Audible alarms will sound to notify you of the power event. The estimated run time will be displayed on the LCD.
3.5 Green Mode and Power-Saving Outlets
The Green Mode optimizes efficiency by bypassing internal components when utility power is stable. Power-saving outlets can be configured to automatically turn off connected devices when the master device (e.g., your computer) is turned off or goes into standby, reducing energy consumption.
4. නඩත්තු කිරීම
4.1 බැටරි රැකවරණය සහ ප්රතිස්ථාපනය
The UPS features user-replaceable and hot-swappable batteries, allowing for replacement without powering down connected equipment.
- ස්වයංක්රීය ස්වයං පරීක්ෂණය: The UPS performs periodic self-tests to assess battery health.
- Battery Failure Notification: The UPS will provide an early warning if the battery needs replacement.
- Disconnected Battery Notification: An alarm will sound if the battery is not properly connected.
- ආදේශන ක්රියා පටිපාටිය: Batteries can be replaced without tools. Refer to the specific battery replacement instructions provided with your replacement battery or on the APC support website. Always use genuine APC replacement batteries.
4.2 නැවත සකස් කළ හැකි පරිපථ කඩනය
In case of an overload, the UPS's resettable circuit breaker may trip. Disconnect non-essential equipment, then press the circuit breaker button to reset it.
4.3 පිරිසිදු කිරීම
Keep the UPS clean and free of dust. Use a dry cloth to wipe the exterior. Do not use liquid cleaners or solvents. Ensure ventilation openings are not obstructed.
5. දෝශ නිරාකරණය
This section provides solutions to common issues you might encounter with your APC Back-UPS RS 700 VA.
| ගැටලුව | විය හැකි හේතුව | විසඳුම |
|---|---|---|
| UPS එක on වෙන්නේ නෑ. | Not connected to utility power; battery not charged; internal fault. | Ensure power cord is securely plugged into a live outlet. Allow 24 hours for initial battery charge. If still unresponsive, contact support. |
| ඇසෙන අනතුරු ඇඟවීමේ නාදය නිතර ඇසෙයි. | Overload; battery low/faulty; utility power issues. | Reduce connected load. Check LCD for specific alarm codes. Ensure proper ventilation. Perform a self-test. |
| Building Wiring Fault Indicator is lit. | බිත්ති පිටවානේ රැහැන් ඇදීමේදී ඇතිවන ගැටළුව (උදා: බිම නොමැති වීම, ප්රතිලෝම ධ්රැවීයතාව). | අලෙවිසැල භාවිතා නොකරන්න. රැහැන් පරීක්ෂා කර නිවැරදි කිරීමට සුදුසුකම් ලත් විදුලි කාර්මිකයෙකුගෙන් විමසන්න. |
| Short battery run time. | Battery not fully charged; battery nearing end of life; excessive load. | Ensure battery is fully charged. Reduce connected load. Consider replacing the battery if it's old or fails self-test. |
| UPS not providing power during outage. | Devices connected to surge-only outlets; battery disconnected or faulty. | Verify critical devices are connected to battery-protected outlets. Check for disconnected battery notification. Replace battery if faulty. |
6. පිරිවිතර
- ආකෘතිය: BR700G නිෂ්පාදන විස්තර
- ධාරිතාව: 700 VA / 450 W
- ආදාන වෙළුමtage: 120V AC (නාමික)
- ප්රතිදාන වෙළුමtage: 120V AC (නාමික)
- ප්රතිදාන සම්බන්ධතා: 3 x NEMA 5-15R (Battery Backup & Surge Protection), 3 x NEMA 5-15R (Surge Protection Only)
- ආකෘති සාධකය: කුළුණ
- බර: ආසන්න වශයෙන් 0.01 අවුන්ස (Note: This weight is as per provided data. Actual weight for a UPS of this capacity is typically much higher.)
- Ampකෝපය: 3 Amps
- වර්ණය: කොළ පාටයි (Note: The product image shows a black/dark grey unit, but specifications list 'Green'.)
- පළමු ලබා ගත හැකි දිනය: 12 සැප්තැම්බර් 2012
- නිෂ්පාදකයා: APC
7 වගකීම් සහතිකය
The APC Back-UPS RS 700 VA Tower UPS (Model BR700G) comes with a වසර 1ක නිෂ්පාදකයාගේ වගකීම. This warranty covers defects in materials and workmanship under normal use. For specific terms, conditions, and to initiate a warranty claim, please refer to the official APC warranty documentation or contact APC customer support.
8. සහාය
For technical assistance, product information, or to purchase replacement parts and accessories, please contact APC customer support or visit their official webඅඩවිය.
- APC නිලධාරියා Webඅඩවිය: www.apc.com
- පාරිභෝගික සේවාව: APC වෙත යොමු කරන්න webකලාපීය සම්බන්ධතා තොරතුරු සඳහා අඩවිය.