1. හැඳින්වීම
1.1 නිෂ්පාදනය අවසන්view
The Liberty Pumps Model SXL24=3 is an SX-Series Simplex Pump Control with Alarm, designed to manage the operation of a single pump in various applications. This unit provides reliable control and includes an alarm feature to alert users to specific operational conditions, ensuring efficient and safe pump performance. It is engineered for durability and ease of integration into existing systems.
1.2 ආරක්ෂිත තොරතුරු
අවවාදයයි: Before installation, operation, or maintenance, ensure all power to the pump control system is disconnected at the main electrical panel. Failure to do so can result in serious injury or death from electrical shock.
- Installation and servicing must be performed by qualified personnel in accordance with all local electrical and plumbing codes.
- Do not operate the pump control with damaged wiring or components.
- Ensure the control panel is properly grounded to prevent electrical hazards.
- Keep children and unauthorized personnel away from the pump control system.
- ස්ථාපනය සහ නඩත්තු කිරීමේදී සුදුසු පුද්ගලික ආරක්ෂක උපකරණ (PPE) පළඳින්න.
2. පිහිටුවීම සහ ස්ථාපනය
2.1 ඉවත් කිරීම සහ පරීක්ෂා කිරීම
Carefully remove the SXL24=3 control panel from its packaging. Inspect the unit for any visible damage that may have occurred during shipping. Report any damage to the carrier and supplier immediately.
2.2 පාලක පැනලය සවි කිරීම
Mount the control panel in a dry, accessible location, away from direct sunlight and excessive vibration. Use appropriate fasteners to secure the panel to a sturdy surface. Ensure adequate clearance around the panel for ventilation and future servicing.
2.3 විදුලි සම්බන්ධතා
All electrical wiring must comply with national and local electrical codes. The SXL24=3 operates on 240 Volts and has a current rating of 14.9 Amps. Connect the incoming power supply, pump motor, and float switches to the designated screw terminals inside the control panel. Refer to the wiring diagram located inside the control panel door for specific connections. Ensure all connections are tight and secure.
2.4 Float Switch Installation
Install the float switches at the appropriate levels within the tank or basin to control pump operation and activate the alarm. Typically, one float controls the pump ON level, another controls the pump OFF level, and a third float activates the high-level alarm. Ensure floats are free to move and will not interfere with each other or other tank components.

This image displays two models of the Liberty Pumps SX-Series Simplex Pump Control with Alarm. The units feature a control panel enclosure and multiple float switches extending from the bottom, designed for monitoring and controlling pump operations.
3. මෙහෙයුම් උපදෙස්
3.1 ආරම්භක බල-අප්
After completing all electrical connections and verifying their correctness, restore power to the control panel. The system will perform a self-check. Observe the indicator lights on the panel for normal operation.
3.2 පොම්ප මෙහෙයුම
The SXL24=3 automatically controls the pump based on the liquid levels detected by the float switches. When the liquid level rises to the 'Pump ON' float, the pump will activate. When the liquid level drops to the 'Pump OFF' float, the pump will deactivate.
3.3 අනතුරු ඇඟවීමේ කාර්යය
If the liquid level rises above the 'High Level Alarm' float, the integrated alarm will activate, typically indicated by an audible signal and a visual light. This signifies a potential issue such as pump failure or an unusually high inflow. Silence the audible alarm by pressing the designated button on the control panel, but investigate the cause of the alarm immediately.
4. නඩත්තු කිරීම
4.1 නිතිපතා පරීක්ෂා කිරීම්
Periodically inspect the control panel and float switches for any signs of wear, corrosion, or damage. Ensure all electrical connections remain tight. Check that the float switches move freely and are not obstructed by debris.
4.2 පිරිසිදු කිරීම
Keep the exterior of the control panel clean and free of dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents that could damage the enclosure.
4.3 Float Switch පරීක්ෂාව
Periodically test the float switches by manually raising and lowering them (with power disconnected if accessing inside the tank) to ensure they activate and deactivate the pump and alarm correctly. This should be done by qualified personnel.
5. දෝශ නිරාකරණය
Before attempting any troubleshooting, ensure power is disconnected. If you are unsure about any procedure, contact a qualified technician.
- Pump Not Running: Check power supply, circuit breakers, and float switch positions. Verify pump motor is operational.
- පොම්පය අඛණ්ඩව ක්රියාත්මක වීම: Inspect 'Pump OFF' float switch for obstruction or malfunction. Check for wiring errors.
- Alarm Activating Frequently: Investigate the cause of high liquid levels (e.g., pump failure, clogged discharge line, excessive inflow). Check 'High Level Alarm' float switch for proper operation.
- පැනලයට බලය නැත: Check main circuit breaker and incoming power connections.
6. පිරිවිතර
| විශේෂාංගය | පිරිවිතර |
|---|---|
| ආකෘතිය | SXL24=3 |
| වෙළඳ නාමය | ලිබර්ටි පොම්ප |
| වෙළුමtage | වෝල්ට් 240 |
| වත්මන් ශ්රේණිගත කිරීම | 14.9 Amps |
| සම්බන්ධක වර්ගය | ඉස්කුරුප්පු ඇණ |
| අයිතමයේ බර | පවුම් 13ක් |
| නිෂ්පාදකයා | නිදහස |
| ASIN | B009PRS2IG |
| UPC | 671812112009 |
| පළමු දිනය තිබේ | 12 ඔක්තෝබර් 2012 |
7. වගකීම් සහ සහාය
Specific warranty details for the Liberty Pumps SXL24=3 are not provided in this document. For information regarding product warranty, technical support, or replacement parts, please contact Liberty Pumps directly through their official website or customer service channels. Ensure you have your product model number (SXL24=3) and purchase date available when contacting support.