This manual provides essential information for the proper installation, operation, and maintenance of the Watts Series 335 ASME rated Boiler Pressure Relief Valve. This valve is designed for hydronic systems, specifically for boilers up to 510,000 BTU at a 30 PSI (2.11 bar) set point. Its compact, all-bronze construction makes it suitable for various OEM boiler applications.

Watts 30 PSI Pressure Relief Valve, front view

රූපය 1: ඉදිරිපස view of the Watts 30 PSI Pressure Relief Valve, showing the bronze body and the pressure relief lever.

ආරක්ෂිත තොරතුරු

Always follow local codes and regulations during installation and maintenance. Ensure the system is depressurized and cooled before attempting any work on the valve. Wear appropriate personal protective equipment (PPE).

සැකසුම සහ ස්ථාපනය

The Watts 0342691 Pressure Relief Valve is designed for straightforward installation. It features a 3/4-inch female threaded inlet and a 3/4-inch FNPT outlet.

  1. සකස් කිරීම: Ensure the boiler system is completely shut down, depressurized, and cooled. Drain any water from the system if necessary.
  2. පැරණි කපාටය ඉවත් කරන්න (අදාළ නම්): Carefully unthread the existing pressure relief valve from the boiler.
  3. නූල් සීලන්ට් යොදන්න: Apply an appropriate thread sealant (e.g., PTFE tape or pipe dope) to the male threads of the new Watts valve.
  4. නව කපාටය ස්ථාපනය කරන්න: Thread the new valve into the boiler's pressure relief valve port. Tighten securely with a wrench, ensuring not to overtighten.
  5. Connect Discharge Piping: Attach appropriate discharge piping to the valve's outlet. This piping must be sized correctly and routed to a safe discharge point, preventing scalding or property damage.
  6. System Re-pressurization: Slowly re-pressurize the boiler system and check for any leaks around the newly installed valve and connections.
Watts 30 PSI Pressure Relief Valve, side view

රූපය 2: පැත්ත view of the Watts 30 PSI Pressure Relief Valve, showing the compact design and connection points.

මෙහෙයුම් මූලධර්ම

The Watts 0342691 is an automatic pressure relief valve designed to protect hydronic heating systems from over-pressurization. It is factory-set to open at 30 PSI (Pounds per Square Inch). When the system pressure exceeds this set point, the valve will automatically open, discharging water to relieve the excess pressure and prevent damage to the boiler or system components. Once the pressure drops below the set point, the valve will automatically close.

The valve also features a manual test lever. This lever allows for periodic manual testing of the valve's operation. When the lever is lifted, the valve will open, discharging water. It is important to exercise caution when using the test lever, as hot water may be discharged.

නඩත්තු කිරීම

Regular maintenance ensures the longevity and proper function of your pressure relief valve.

දෝෂගවේෂණය

ගැටලුවවිය හැකි හේතුවවිසඳුම
Valve constantly dripping or leaking
  • පද්ධතියේ පීඩනය වැඩියි
  • Sediment or debris under the seat
  • Worn or damaged internal components
  • Improper installation (e.g., insufficient thread sealant)
  • Check system pressure; ensure it is below 30 PSI.
  • Briefly lift the test lever to flush out debris.
  • If leaking persists, the valve may need replacement.
  • Re-install with proper thread sealant if leak is from threads.
Valve does not open when pressure is high
  • Valve seized due to corrosion or lack of use
  • Incorrect valve installed (wrong pressure setting)
  • Attempt to operate the manual test lever.
  • If it remains seized, the valve must be replaced immediately to prevent system damage.
  • Verify the valve's pressure rating matches system requirements.

පිරිවිතර

Watts 30 PSI Pressure Relief Valve with dimensions shown against a hand

Figure 3: The Watts 30 PSI Pressure Relief Valve demonstrating its compact size, approximately 2.9 inches (7 cm) in height.

ගුණාංගයවටිනාකම
ආදර්ශ අංකයWATTS - 118946
ද්රව්යලෝකඩ
ආදාන සම්බන්ධතා ප්‍රමාණය3/4 අඟල්
ආදාන සම්බන්ධතා වර්ගයFemale Threaded
Outlet සම්බන්ධතා ප්රමාණය3/4 අඟල්
පිටවන සම්බන්ධතා වර්ගයFNPT
උපරිම මෙහෙයුම් පීඩනයPSI 30 (බාර් 2.11)
BTU ශ්‍රේණිගත කිරීම510,000 BTU දක්වා
වරායන් ගණන2
මානයන් (L x W x H)අඟල් 3 x 2.3 x 1.8
බර0.01 ounces (Note: This seems unusually low, likely a data entry error in source. Actual weight for such a valve would be higher.)
පිරිවිතර මෙට්ASME Section IV

වගකීම් තොරතුරු

Specific warranty details for this product are not provided in this manual. Please refer to the manufacturer's official website or contact Watts customer service for current warranty terms and conditions.

සහාය සහ සම්බන්ධතා

For technical assistance, replacement parts, or further information, please contact Watts customer support or visit their official webඅඩවිය.

Watts Official Webඅඩවිය: www.watts.com

Watts Store on Amazon: Visit the Watts Store

අදාළ ලියකියවිලි - WATTS - 118946

පෙරview Watts LF1L, LF1XL, LF10L, LF100XL Temperature and Pressure Relief Valves - Technical Specification
Detailed technical specification for Watts Series LF1L, LF1XL, LF10L, and LF100XL Lead Free Temperature and Pressure Relief Valves, including features, specifications, dimensions, and safety warnings.
පෙරview හයිඩ්‍රොලික් චෙක් විශේෂාංගය සහිත වොට්ස් පීඩන අඩු කිරීමේ කපාටය - මල නොබැඳෙන ශ්‍රේණිය
තාක්ෂණික ඉවරයිview වොට්ස් ACV සංයෝජන පීඩන අඩු කිරීමේ සහ චෙක් කපාටයේ, එහි ක්‍රියාකාරිත්වය, ස්ථාපන මාර්ගෝපදේශ සහ අදාළ පාලන කපාට ආකෘති ලැයිස්තුවක් විස්තර කරයි.
පෙරview Installation Instructions for Watts Sensor Control Monitor Connection Kit
Comprehensive installation guide for the Watts Sensor Control Monitor Connection Kit, detailing setup, wiring, configuration, and integration with BAS and Nexa platforms. Includes safety information and product specifications.
පෙරview Watts W-M115 ACV Pressure Reducing Valve: Specification & Installation Guide
Comprehensive guide detailing the specifications, dimensions, flow rates, operating principles, installation, and start-up procedures for the Watts W-M115 ACV Pressure Reducing Valve. Essential information for industrial and commercial applications.
පෙරview Watts BMS Flood Sensor Retrofit Connection Kit Installation Guide
This guide provides detailed installation instructions for the Watts BMS Flood Sensor Retrofit Connection Kit (Model IS-RFK-FS-ReliefValve-BMS). It covers kit components, requirements, preparation, installation steps, wiring diagrams, and warranty information for monitoring relief valve discharge lines.
පෙරview පිරිවිතර තාක්‍ෂණ මාලාව වොට් SL100XL, L100XL, LL100XL, LLL100XL
පිරිවිතර ශිල්පීය ක්‍රම සම්පූර්ණ වන්නේ les soupapes de décharge température et pression à tige allongée Watts Series SL100XL, L100XL, LL100XL සහ LLL100XL. විස්තර sur les caractéristiques, මානයන්, ස්ථාපනය et sécurité pour chauffe-eau.