MSA 801582

MSA Safety 801582 Sample Probe Passport Water Stop Filter Instruction Manual

මාදිලිය: 801582

1. හැඳින්වීම

This instruction manual provides essential information for the proper installation, operation, and maintenance of the MSA Safety 801582 Sample Probe Passport Water Stop Filter. This product is designed to prevent water ingress into gas detection equipment, ensuring accurate readings and protecting sensitive internal components. Please read this manual thoroughly before use to ensure safe and effective operation.

2. නිෂ්පාදන අවසන්view සහ සංරචක

The MSA Safety 801582 Water Stop Filter is a critical accessory for sample probe systems, designed to halt the flow of water and protect connected instruments. Each pack contains 10 individual filters.

Pack of 10 MSA Safety 801582 Water Stop Filters

රූපය 1: A pack of ten MSA Safety 801582 Sample Probe Passport Water Stop Filters. These filters are designed to prevent water from entering gas detection equipment.

Each filter unit consists of a durable plastic housing with inlet and outlet ports, containing a specialized membrane or material that stops water while allowing gas samples to pass through. The compact design facilitates easy integration into existing sample රේඛා.

Close-up of a single MSA Safety 801582 Water Stop Filter

රූපය 2: සවිස්තරාත්මක view of a single MSA Safety 801582 Water Stop Filter, showing its clear plastic body and connection ports. The filter is marked with "ADVANTEC JP050AN".

3. පිහිටුවීම සහ ස්ථාපනය

Proper installation is crucial for the effective performance of the water stop filter. Follow these steps carefully:

  1. සම්බන්ධතා ලක්ෂ්‍ය හඳුනා ගන්න: s තීරණය කරන්නample line where water ingress is a potential issue. The filter should be installed between the sample probe and the gas detection instrument.
  2. ගැළපුම සහතික කරන්න: Verify that the filter's connection ports are compatible with your existing sample tubing. The filter is designed for use with MSA Passport systems.
  3. Orient Correctly: Observe the flow direction indicated on the filter body (if present) or ensure the filter is positioned to intercept water before it reaches the instrument. Typically, the wider end connects to the sample source, and the narrower end to the instrument.
  4. ආරක්ෂිත සම්බන්ධතා: s සම්බන්ධ කරන්නample tubing securely to both the inlet and outlet ports of the filter. Ensure all connections are tight to prevent leaks, which could compromise sample integrity or filter effectiveness.
  5. පරීක්ෂණ පද්ධතිය: After installation, perform a system leak test according to your gas detection equipment's manual to confirm proper sealing and functionality.

Warning: Do not force connections. Incorrect installation can lead to leaks or damage to the filter and connected equipment.

4. මෙහෙයුම් උපදෙස්

Once installed, the MSA Safety 801582 Water Stop Filter operates passively as part of your sample line. It requires no active user input during normal operation.

  • අඛණ්ඩ අධීක්ෂණය: The filter continuously prevents water from reaching your gas detection sensor while allowing the gas sample to pass through.
  • දෘශ්‍ය පරීක්ෂාව: Periodically inspect the transparent body of the filter for any signs of accumulated water or discoloration, which indicates the filter is performing its function and may require replacement.
  • ප්රවාහ සීමා කිරීම: A significant accumulation of water or particulate matter within the filter may cause a noticeable restriction in sample flow. This is an indication that the filter needs immediate replacement.

5. නඩත්තු කිරීම

The MSA Safety 801582 Water Stop Filter is a disposable component and is not designed for cleaning or reuse. Regular inspection and timely replacement are the primary maintenance activities.

  • පරීක්ෂණ වාර ගණන: Inspect the filter daily or before each use, especially in environments where water exposure is likely.
  • ආදේශනය: Replace the filter immediately if:
    • Water is visible inside the filter housing.
    • There is a noticeable reduction in sample ගලා.
    • The filter material appears discolored or damaged.
    • The filter has been exposed to a significant amount of moisture.
  • බැහැර කිරීම: Dispose of used filters according to local regulations for industrial waste.
  • ගබඩා: Store unused filters in their original packaging in a cool, dry place, away from direct sunlight and extreme temperatures.

6. දෝශ නිරාකරණය

ගැටලුව විය හැකි හේතුව විසඳුම
Reduced sample flow to instrument Filter is clogged with water or particulate matter. Replace the water stop filter.
Water detected in gas detection instrument Filter is compromised or improperly installed. Inspect filter for damage. Ensure connections are secure. Replace filter if necessary.
Filter appears discolored or damaged Exposure to harsh chemicals or physical stress. පෙරහන වහාම ප්‍රතිස්ථාපනය කරන්න.

7. පිරිවිතර

විශේෂාංගය විස්තර
ආදර්ශ අංකය 801582
නිෂ්පාදන වර්ගය Sample Probe Passport Water Stop Filter
වෙළඳ නාමය MSA ආරක්ෂාව
ද්රව්ය Durable Plastic (Filter Body), Stainless Steel (Internal/Connectors - as per manufacturer specifications)
නිෂ්පාදන මානයන් 3 x 2 x 0.1 inches (approximate, individual filter)
අයිතමයේ බර 0.48 ounces (individual filter)
ඒකක ගණන පැකට්ටුවකට පෙරහන් 10ක්
බාහිර පරීක්ෂණ සහතික කිරීම CE
UPC 641817010266
ප්‍රාථමික ප්‍රතිලාභය Prevents water ingress, reduces PFAS (as per product benefits)

8. වගකීම් සහ සහාය

For specific warranty information regarding the MSA Safety 801582 Sample Probe Passport Water Stop Filter, please refer to the documentation provided with your original purchase or contact MSA Safety directly. As a consumable item, filters typically have a limited warranty against manufacturing defects.

For technical support, product inquiries, or to purchase replacement filters, please visit the official MSA Safety webවෙබ් අඩවිය හෝ ඔවුන්ගේ පාරිභෝගික සේවා දෙපාර්තමේන්තුව අමතන්න. ඔබට වැඩිදුර තොරතුරු සොයා ගත හැක MSA Safety Store on Amazon හෝ ඔවුන්ගේ ආයතනික webඅඩවිය.

අදාළ ලියකියවිලි - 801582

පෙරview MSA A2 මෘදුකාංග මෙහෙයුම් අත්පොත: වගවීමේ පාලනය
තීරණාත්මක මෙහෙයුම් වලදී SCBA වැනි ආරක්ෂක උපකරණ සහ අදාළ උපාංග තත්‍ය කාලීනව නිරීක්ෂණය කිරීම සඳහා නිර්මාණය කර ඇති වගවීමේ පාලන පද්ධතියක් වන MSA A2 මෘදුකාංගය සඳහා වන පුළුල් මෙහෙයුම් අත්පොත. වැඩිදියුණු කළ ආරක්ෂක කළමනාකරණය සඳහා සැකසුම, භාවිතය සහ විශේෂාංග ආවරණය කරයි.
පෙරview MSA ALTAIR io 4 ගෑස් හඳුනාගැනීමේ පැළඳිය හැකි පරිශීලක මාර්ගෝපදේශය
මෙම පරිශීලක මාර්ගෝපදේශය MSA ALTAIR io 4 ගෑස් හඳුනාගැනීමේ පැළඳිය හැකි සඳහා ආරක්ෂක දැන්වීම්, සැකසුම, ක්‍රියාකාරිත්වය, විශේෂාංග, නඩත්තුව සහ දෝශ නිරාකරණය ආවරණය කරමින් සවිස්තරාත්මක උපදෙස් සපයයි.
පෙරview MSA A2 මෘදුකාංග මෙහෙයුම් අත්පොත: වගවීමේ පාලනය
Comprehensive operating manual for MSA A2 Software, detailing its features for real-time accountability control and monitoring of SCBA and personnel during critical operations.
පෙරview MSA F2 X-TREM ආරක්ෂිත හිස්වැසුම් පරිශීලක අත්පොත
MSA F2 X-TREM හිස්වැස්ම යනු වනගත ගිනි නිවීම්, ගලවා ගැනීමේ මෙහෙයුම් සහ කඳු නැගීම ඇතුළු විවිධ යෙදුම් සඳහා නිර්මාණය කර ඇති බහුකාර්ය ආරක්ෂිත හිස්වැස්මකි. මෙම පරිශීලක අත්පොත එහි නිවැරදි භාවිතය, ගැලපීම, නඩත්තුව සහ පවතින උපාංග පිළිබඳ අත්‍යවශ්‍ය තොරතුරු සපයන අතර, ප්‍රශස්ත ආරක්ෂාව සහ කාර්ය සාධනය සහතික කරයි.
පෙරview MSA ALTAIR Pro තනි ගෑස් අනාවරක මෙහෙයුම් අත්පොත - ආරක්ෂාව සහ භාවිත මාර්ගෝපදේශය
මෙම මෙහෙයුම් අත්පොත MSA ALTAIR Pro තනි ගෑස් අනාවරකය සඳහා සවිස්තරාත්මක උපදෙස්, ආරක්ෂක මාර්ගෝපදේශ, ක්‍රමාංකන ක්‍රියා පටිපාටි සහ දෝශ නිරාකරණය සපයයි. ඔබේ ගෑස් හඳුනාගැනීමේ උපකරණය ඵලදායී ලෙස භාවිතා කර නඩත්තු කරන්නේ කෙසේදැයි ඉගෙන ගන්න.
පෙරview Manuel d'utilisation Centrale GasGard XL, Montage Mural MSA
Manuel d'utilisation complet pour la centrale d'alarme gaz MSA GasGard XL, montage mural. Instructions d'installation, d'utilisation, de configuration et de maintenance pour la sécurité industrielle.