This manual provides essential information for the safe and efficient installation, operation, and maintenance of the ABB 3HAC 15424-1 Transformer. This industrial-grade transformer is designed to convert electrical voltages from 400-475V to 230-115V, with a power rating of 4.17 KVA. Please read this manual thoroughly before using the product.
2 ආරක්ෂිත තොරතුරු
Always prioritize safety when working with electrical equipment. Failure to follow safety instructions can result in serious injury or equipment damage.
- සුදුසුකම් ලත් පුද්ගලයින් පමණි: Installation, maintenance, and repair should only be performed by qualified and authorized personnel.
- බලය විසන්ධි කරන්න: Always disconnect all power sources before performing any installation, maintenance, or inspection. Verify zero voltage with appropriate testing equipment.
- භූගත කිරීම: Ensure the transformer is properly grounded according to local and national electrical codes.
- පාරිසරික තත්ත්වයන්: Operate the transformer within specified environmental conditions (temperature, humidity) to prevent overheating or damage.
- පුද්ගලික ආරක්ෂක උපකරණ (PPE): Use appropriate PPE, including insulated gloves, safety glasses, and arc-flash protection, when working with live electrical circuits.
3. පිහිටුවීම සහ ස්ථාපනය
Proper installation is crucial for the safe and reliable operation of the ABB 3HAC 15424-1 Transformer. Consult a qualified electrician for installation.
- සවි කිරීම: Securely mount the transformer in a well-ventilated area, away from flammable materials and excessive moisture. Ensure adequate clearance for cooling and access.
- රැහැන් සම්බන්ධතා:
- Connect the primary (input) side to the 400-475V AC supply.
- Connect the secondary (output) side to the 230-115V AC load.
- Ensure all connections are tight and secure to prevent loose contacts and arcing.
- Verify correct phasing සහ වෙළුමtage settings before applying power.
- භූගත කිරීම: Connect the transformer's ground terminal to a reliable earth ground.
- පූර්ව බල පරීක්ෂාව: Before applying power, visually inspect all connections, ensure no foreign objects are present, and confirm all safety covers are in place.

රූපය 1: ඉදිරිපස view of the ABB 3HAC 15424-1 Transformer, showing its robust construction.

රූපය 2: පැත්ත view of the ABB 3HAC 15424-1 Transformer, highlighting connection points.

Figure 3: Product label showing the model number 3HAC 15424-1 and revision.
4. මෙහෙයුම් උපදෙස්
Once properly installed and verified, the transformer is ready for operation.
- බල ගැන්වීම: Apply power to the primary side of the transformer.
- වෙළුමtagඊ සත්යාපනය: ප්රතිදාන පරිමාව සත්යාපනය කිරීමට බහුමාපකයක් භාවිතා කරන්නtage on the secondary side matches the expected 230-115V range before connecting the load.
- පැටවීමේ සම්බන්ධතාවය: Connect the intended load to the secondary terminals. Ensure the load does not exceed the transformer's 4.17 KVA rating.
- අධීක්ෂණය: Periodically monitor the transformer for unusual noises, excessive heat, or smoke. Immediately disconnect power if any abnormalities are detected.
- විදුලිය විසන්ධි කිරීම: To shut down, disconnect the load first, then remove power from the primary side.
5. නඩත්තු කිරීම
Regular maintenance ensures the longevity and safe operation of your transformer.
- වරින් වර පරීක්ෂා කිරීම: Annually inspect the transformer for signs of wear, corrosion, loose connections, or insulation damage.
- පිරිසිදු කිරීම: With power disconnected, gently clean the exterior of the transformer to remove dust and debris. Ensure ventilation openings are clear. Do not use liquids directly on electrical components.
- සම්බන්ධතා චෙක්පත්: Periodically check all electrical connections for tightness. Loose connections can cause overheating and arcing.
- පාරිසරික පරීක්ෂාව: මෙහෙයුම් පරිසරය නිශ්චිත උෂ්ණත්වය සහ ආර්ද්රතා සීමාවන් තුළ පවතින බවට සහතික වන්න.
6. දෝශ නිරාකරණය
Refer to the following table for common issues and their potential solutions. Always disconnect power before attempting any troubleshooting or repair.
| ගැටලුව | විය හැකි හේතුව | විසඳුම |
|---|---|---|
| ප්රතිදාන වෙළුම නැතtage | No input power; Blown fuse/tripped breaker; Internal fault | Check input power supply; Inspect and replace fuse/reset breaker; Contact qualified service personnel. |
| වැරදි ප්රතිදාන පරිමාවtage | Incorrect wiring; Overload; Internal fault | Verify wiring connections; Reduce load; Contact qualified service personnel. |
| අධික උනුසුම් වීම | Overload; Poor ventilation; High ambient temperature | Reduce load; Ensure adequate ventilation; Relocate transformer to a cooler environment. |
| Unusual noise (humming, buzzing) | Loose laminations; Overload; Internal fault | Check for loose mounting; Reduce load; Contact qualified service personnel. |
7. පිරිවිතර
| පරාමිතිය | වටිනාකම |
|---|---|
| ආදර්ශ අංකය | 3HAC 15424-1 |
| ආදාන වෙළුමtage | 400-475V ඒසී |
| ප්රතිදාන වෙළුමtage | 230-115V ඒසී |
| බල ශ්රේණිගත කිරීම | 4.17 කේ.වී.ඒ |
| බර | රාත්තල් 72.00 (දළ වශයෙන් කිලෝග්රෑම් 32.66) |
| නිෂ්පාදන මානයන් (L x W x H) | 12.00 x 12.00 x 12.00 අඟල් (ආසන්න වශයෙන් 30.48 x 30.48 x 30.48 සෙ.මී.) |
| නිෂ්පාදකයා | ඒබීබී |
සටහන: පිරිවිතර දැනුම්දීමකින් තොරව වෙනස් විය හැකිය. වඩාත් නිවැරදි තොරතුරු සඳහා සෑම විටම නිෂ්පාදන ලේබලය වෙත යොමු වන්න.
8. වගකීම් සහ සහාය
For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact ABB customer support directly. General warranty typically covers manufacturing defects for a specified period.
For technical support, service, or spare parts, please contact your local ABB representative or visit the official ABB website. When contacting support, please have your model number (3HAC 15424-1) and serial number ready.
ABB නිලධාරියා Webඅඩවිය: www.abb.com