ASHCROFT 1009AWL

ASHCROFT 1009AWL Pressure Gauge User Manual

Model: 1009AWL | Range: 0 to 400 psi

1. හැඳින්වීම

This manual provides essential information for the proper installation, operation, and maintenance of your ASHCROFT 1009AWL Pressure Gauge. This general-purpose pressure gauge is designed for reliable measurement within a 0 to 400 psi range, featuring a 2-1/2 inch dial and liquid-filled construction for enhanced performance and durability.

ආරක්ෂිත සහ කාර්යක්ෂම ක්‍රියාකාරිත්වය සහතික කිරීම සඳහා නිෂ්පාදිතය භාවිතා කිරීමට පෙර කරුණාකර මෙම අත්පොත හොඳින් කියවන්න.

2 ආරක්ෂිත තොරතුරු

  • පීඩන සීමාවන්: Do not exceed the maximum rated pressure of 400 psi. Over-pressurization can cause gauge failure and potential injury.
  • ස්ථාපනය: Ensure the gauge is installed by qualified personnel using appropriate tools and sealing methods.
  • පද්ධති අනුකූලතාව: Verify that the gauge's wetted parts (Brass/Bronze) are compatible with the process media to prevent corrosion or damage.
  • උෂ්ණත්ව සීමාවන්: Operate the gauge within the specified temperature range of -20°F to 150°F. Extreme temperatures can affect accuracy and lifespan.
  • හැසිරවීම: Avoid dropping or subjecting the gauge to severe impact, as this can damage internal components.

3. නිෂ්පාදන අවසන්view සහ සංරචක

The ASHCROFT 1009AWL Pressure Gauge is constructed for durability and accurate readings. Key components include:

  • අමතන්න: 2-1/2 inch diameter, clearly marked with 0-400 psi scale.
  • දර්ශකය: Indicates the measured pressure.
  • නඩුව: Made from 304 Stainless Steel for corrosion resistance.
  • කාච: Polycarbonate material for visibility and protection.
  • සම්බන්ධතාවය: 1/4 inch MNPT (Male National Pipe Taper) located at the bottom of the gauge.
  • තෙත් කරන ලද කොටස්: Brass/Bronze construction ensures compatibility with various media.
  • Liquid Filling: Glycerin-filled for dampening pulsation and vibration, enhancing pointer stability and extending gauge life.
ASHCROFT 1009AWL Pressure Gauge, 0-400 psi

රූපය 1: ASHCROFT 1009AWL Pressure Gauge. This image displays the front view of the pressure gauge, showing the 0-400 psi dial, the ASHCROFT brand logo, and the bottom-mounted 1/4 inch MNPT connection.

4. ස්ථාපනය සහ සැකසුම

  1. Inspect Gauge: Before installation, visually inspect the gauge for any signs of damage. Do not install a damaged gauge.
  2. Prepare Connection: Ensure the system connection point is clean and free of debris.
  3. සීලන්ට් යොදන්න: Apply an appropriate thread sealant (e.g., PTFE tape or pipe dope) to the 1/4 inch MNPT threads of the gauge connection. Ensure sealant does not enter the gauge or system.
  4. Thread Gauge: Carefully thread the gauge into the system connection by hand until finger-tight.
  5. තද කරන්න: Using a wrench on the wrench flats of the gauge connection (not the case), tighten the gauge until secure. Avoid over-tightening, which can damage the threads or the gauge.
  6. දිශානතිය සත්‍යාපනය කරන්න: Ensure the gauge dial is oriented for easy reading.
  7. System Pressurization: Slowly pressurize the system and check for leaks at the connection point.

5. මෙහෙයුම

The ASHCROFT 1009AWL Pressure Gauge is designed for straightforward operation. Once properly installed, the gauge will continuously display the system pressure.

  • Reading the Gauge: Observe the pointer's position on the dial. The primary scale is in psi (pounds per square inch), ranging from 0 to 400. The smallest graduation is 10 psi.
  • මෙහෙයුම් කොන්දේසි: Ensure the operating environment and process media remain within the gauge's specified temperature range of -20°F to 150°F.
  • නිරවද්යතාව: The gauge provides readings with an accuracy of +/-1.50% of full scale.
  • ස්පන්දනය: The glycerin filling helps to dampen pointer fluctuation in systems with pulsation or vibration, providing a more stable reading.

6. නඩත්තු කිරීම

Regular maintenance ensures the longevity and accuracy of your pressure gauge.

  • සාමාන්ය පරීක්ෂාව: Periodically inspect the gauge for any physical damage, such as a cracked lens, bent pointer, or corroded case.
  • පිරිසිදුකම: Keep the gauge lens clean to ensure clear visibility of the dial. Use a soft, damp පිරිසිදු කිරීම සඳහා රෙදි; උල්ෙල්ඛ පිරිසිදු කරන්නන්ගෙන් වළකින්න.
  • නැවත ක්‍රමාංකනය: While ASHCROFT gauges are built for accuracy, prolonged use or exposure to harsh conditions may necessitate recalibration. Consult a qualified technician for recalibration services if accuracy is critical and suspected to be compromised.
  • Liquid Fill: The glycerin fill is sealed. If the liquid level appears significantly low or cloudy, the gauge may require replacement or professional servicing.

7. දෝශ නිරාකරණය

Below are common issues and potential solutions for the ASHCROFT 1009AWL Pressure Gauge:

  • No Reading / Pointer Stuck:
    • Verify that the system is pressurized.
    • Check for blockages in the connection line to the gauge.
    • Inspect for physical damage to the gauge.
  • Inaccurate Reading:
    • Ensure the gauge is operating within its specified temperature range.
    • Confirm the gauge's range is appropriate for the system pressure.
    • Consider professional recalibration if accuracy is critical and other factors are ruled out.
  • Leak at Connection:
    • පද්ධතිය අවපාත කරන්න.
    • Re-apply thread sealant and re-tighten the connection.
    • Inspect threads for damage.
  • Liquid Fill Discoloration/Loss:
    • This may indicate a seal compromise or internal issue. The gauge may need replacement.

8. තාක්ෂණික පිරිවිතර

ආදර්ශ මාලාව1009AWL යනු කුමක්ද?
පීඩන පරාසය0 සිට 400 psi දක්වා
නිරවද්යතාව+/-1.50% of full scale
Nominal Dial Sizeඅඟල් 2-1/2
සම්බන්ධතා ප්රමාණය1/4 inch MNPT
සම්බන්ධතා ස්ථානයපහළ
නඩු ද්රව්ය304 මල නොබැඳෙන වානේ
තෙත් කොටස්Brass / Bronze
කාච ද්රව්යපොලිකාබනේට්
Liquid FilledYes (Glycerin)
මෙහෙයුම් උෂ්ණත්ව පරාසය-20°F සිට 150°F (-29°C සිට 66°C)
නිෂ්පාදන මානයන් (L x W x H)අඟල් 4 x 3 x 1
අයිතමයේ බරපවුම් 1 කි
UPC759426066021

9. වගකීම් තොරතුරු

The ASHCROFT 1009AWL Pressure Gauge comes with a වසර 5ක නිෂ්පාදකයාගේ වගකීමක්. This warranty covers defects in materials and workmanship under normal use and service. For specific terms and conditions, please refer to the official ASHCROFT warranty statement or contact ASHCROFT customer support.

10. පාරිභෝගික සහාය

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact ASHCROFT customer support directly. Visit the official ASHCROFT webසම්බන්ධතා තොරතුරු සහ අමතර සම්පත් සඳහා අඩවිය.

ASHCROFT Official Webඅඩවිය: www.ashcroft.com

අදාළ ලියකියවිලි - 1009AWL යනු කුමක්ද?

පෙරview Ashcroft B400 සහ B700 Snap Action Pressure Switch ස්ථාපනය සහ නඩත්තු මාර්ගෝපදේශය
මෙම මාර්ගෝපදේශය Ashcroft B400 සහ B700 ශ්‍රේණි ස්නැප් ක්‍රියාකාරී පීඩන ස්විච ස්ථාපනය සහ නඩත්තුව සඳහා අත්‍යවශ්‍ය තොරතුරු සපයයි. එය නිෂ්පාදනය පුරා ආවරණය කරයිview, dimensions, mounting, electrical and conduit connections, setpoint adjustment procedures, and recommended practices for safe and reliable operation.
පෙරview Ashcroft මාදිලිය 1130 සහ 1140 අවකල පීඩන මානය/ස්විච් ස්ථාපන උපදෙස්
විකල්ප ස්විච සහිත Ashcroft Model 1130 සහ 1140 අවකල පීඩන මාපක සඳහා ස්ථාපන උපදෙස් සහ තාක්ෂණික විස්තර. මෙහෙයුම් මූලධර්ම, ස්ථාපනය, පූර්වාරක්ෂාවන් සහ ස්විච රැහැන් ඇදීම ආවරණය කරයි.
පෙරview Ashcroft S1 Pressure Transducer: Features, Specifications, and Ordering Guide
Comprehensive data sheet for the Ashcroft S1 Pressure Transducer, detailing its features, typical uses, technical specifications, environmental and electrical ratings, output signals, ordering codes, and dimensional information.
පෙරview Ashcroft RXLdp උපදෙස් පත්‍රිකාව: ස්ථාපනය සහ මෙහෙයුම් මාර්ගෝපදේශය
Ashcroft Model RXLdp අඩු අවකල පීඩන පරිවර්තකය සඳහා සවිස්තරාත්මක උපදෙස් පත්‍රිකාව, ආරක්ෂක අනතුරු ඇඟවීම්, විස්තරය, සවි කිරීම, නල මාර්ග, බල අවශ්‍යතා, විදුලි සම්බන්ධතා සහ මානයන් ආවරණය කරයි.
පෙරview Ashcroft S10 & S50 RTD සහ තාපකූප ස්ථාපනය සහ නඩත්තු මාර්ගෝපදේශය
Ashcroft S10 සහ S50 RTD සහ තාපකූපළ උෂ්ණත්ව සංවේදක සඳහා සවිස්තරාත්මක ස්ථාපන සහ නඩත්තු උපදෙස් සපයයි. නිවැරදි මිනුම් සහ කල්පැවැත්ම සහතික කිරීම සඳහා සාමාන්‍ය පූර්වාරක්ෂාවන්, ගබඩා කිරීම, RTD සහ තාපකූපළ සඳහා නිශ්චිත ස්ථාපන ක්‍රියා පටිපාටි සහ නඩත්තු මාර්ගෝපදේශ ආවරණය කරයි.
පෙරview Ashcroft ZX12 අධි සංශුද්ධතා පීඩන සම්ප්‍රේෂකය: ස්ථාපනය සහ නඩත්තු මාර්ගෝපදේශය
Ashcroft ZX12 අධි සංශුද්ධතා පීඩන සම්ප්‍රේෂකය සඳහා සවිස්තරාත්මක ස්ථාපන සහ නඩත්තු උපදෙස්, ආරක්ෂිත පූර්වාරක්ෂාවන්, රැහැන් ඇදීම, ක්‍රියාකාරිත්වය, ක්‍රමාංකනය සහ වගකීම් තොරතුරු ආවරණය කරයි.