Extech PH90

Extech PH90 Waterproof pH Meter Instruction Manual

මාදිලිය: PH90

1. නිෂ්පාදන අවසන්view

The Extech PH90 Waterproof pH Meter is a precision instrument designed for accurate pH measurement across various applications, including water quality testing, hydroponics, aquaculture, swimming pools, beverage production, and laboratory use. This device features a robust waterproof housing, a replaceable electrode, 3-point automatic calibration, and auto buffer recognition for ease of use and reliable results. Its compact design makes it suitable for both field and professional environments.

Extech PH90 Waterproof pH Meter

Figure 1: Extech PH90 Waterproof pH Meter. This image shows the compact, handheld pH meter with its digital display and control buttons, ready for use.

2 ප්රධාන ලක්ෂණ

3. සැකසීම සහ සකස් කිරීම

3.1. බැටරි ස්ථාපනය

The PH90 meter requires two CR2032 Lithium Metal batteries (included). To install or replace batteries:

  1. Unscrew the battery compartment cap located at the top of the meter.
  2. Insert the two CR2032 batteries, ensuring correct polarity (+/-).
  3. බැටරි මැදිරි පියන ආරක්ෂිතව නැවත ස්ථානයට ඉස්කුරුප්පු කරන්න.

3.2. Electrode Preparation

Before first use, and after storage, prepare the electrode:

  1. Remove the protective cap from the electrode tip. The cap contains a moist sponge to keep the electrode hydrated.
  2. Rinse the electrode tip thoroughly with distilled or deionized water. Do not wipe the electrode, as this can create static charges.
  3. Allow any excess water to drip off.

3.3 මූලික ක්රමාංකනය

For optimal accuracy, perform a 3-point calibration before initial use and periodically thereafter. Calibration buffers (pH 4, 7, and 10) are sold separately.

  1. Turn on the meter by pressing the සක්රිය / අක්රිය බොත්තම.
  2. Immerse the electrode into a pH 7.00 buffer solution.
  3. ඔබා අල්ලාගෙන සිටින්න CAL button until "CAL" appears on the display. The meter will automatically recognize the buffer and calibrate.
  4. ආස්රැත ජලය සමග ඉලෙක්ට්රෝඩය සේදීම.
  5. Repeat the process with pH 4.00 and pH 10.00 buffer solutions. The meter will automatically detect and calibrate to these points.
  6. Once calibration is complete, the meter will return to measurement mode.
Extech PH90 Meter Display and Buttons

Figure 2: Close-up of the Extech PH90 display and control buttons, including ON/OFF, MODE, and CAL buttons.

4. මෙහෙයුම් උපදෙස්

4.1. මිනුම් ගැනීම

  1. Ensure the meter is calibrated.
  2. Rinse the electrode with distilled water and gently shake off excess.
  3. Immerse the electrode tip into the sample solution, ensuring the sensor is fully submerged.
  4. Gently stir the solution to ensure homogeneity and allow the reading to stabilize. This may take up to a minute, especially if the sample temperature differs significantly from the meter's previous environment.
  5. Read the pH value displayed on the LCD screen. The temperature will also be displayed.
  6. After measurement, rinse the electrode thoroughly with distilled water.

4.2. රඳවා ගැනීමේ කාර්යය

To freeze the current reading on the display, press the අල්ලා ගන්න button (if available, typically integrated with MODE or a separate button). Press it again to release the hold and return to live measurement.

4.3. Automatic Temperature Compensation (ATC)

The Extech PH90 features Automatic Temperature Compensation, which adjusts pH readings based on the sample's temperature, ensuring accuracy across varying temperatures. The temperature is displayed alongside the pH value.

5. නඩත්තු කිරීම

5.1. Electrode Care and Storage

Proper electrode care is crucial for maintaining accuracy and extending the life of your meter:

Extech PH90 Electrode Tip

Figure 3: Close-up of the Extech PH90's replaceable electrode tip, which requires proper care and storage.

5.2. ඉලෙක්ට්රෝඩ ප්රතිස්ථාපනය

The PH90 features a replaceable electrode. If the electrode performance degrades significantly despite proper cleaning and calibration, it may need replacement. Refer to the Extech website or contact customer support for information on purchasing replacement electrodes (Part PH95).

5.3. බැටරි ප්රතිස්ථාපනය

When the battery indicator appears on the display or the meter fails to power on, replace the two CR2032 Lithium Metal batteries as described in Section 3.1.

6. දෝශ නිරාකරණය

ගැටලුවවිය හැකි හේතුවවිසඳුම
සාවද්‍ය හෝ අස්ථායී කියවීම්
  • Electrode not calibrated
  • Dirty or dry electrode
  • Temperature not equilibrated
  • Expired buffer solutions
  • හානියට පත් ඉලෙක්ට්රෝඩය
  • Perform a 3-point calibration.
  • Clean the electrode and ensure it is properly stored.
  • Allow sufficient time for the meter's temperature sensor to equilibrate with the sample.
  • Use fresh calibration buffer solutions.
  • ඉලෙක්ට්රෝඩය ප්රතිස්ථාපනය කරන්න.
මීටරය ක්‍රියාත්මක නොවේ
  • මිය ගිය බැටරි
  • වැරදි බැටරි ස්ථාපනය
  • බැටරි නව CR2032 සෛල සමඟ ප්‍රතිස්ථාපනය කරන්න.
  • බැටරි ධ්‍රැවීයතාව පරීක්ෂා කරන්න.
"CAL" error during calibration
  • වැරදි බෆර විසඳුමක් භාවිතා කර ඇත
  • Contaminated buffer solution
  • Electrode issue
  • Ensure correct pH buffer (4, 7, or 10) is used.
  • Use fresh, uncontaminated buffer solutions.
  • Clean or replace the electrode.

7. පිරිවිතර

පරාමිතියවටිනාකම
ආදර්ශ අංකයPH90
pH පරාසයpH අගය 0 ​​සිට 14 දක්වා
pH නිරවද්‍යතාවය± 0.01 pH
උෂ්ණත්ව පරාසය(Not explicitly stated, but integrated for ATC)
බලශක්ති ප්රභවය2 x CR2032 Lithium Metal batteries
අයිතමයේ බරඅවුන්ස 2.88 (ආසන්න වශයෙන් ග්‍රෑම් 81.6)
නිෂ්පාදන මානයන්6.7 x 1.4 x 1.4 අඟල් (ආසන්න වශයෙන් 17 x 3.6 x 3.6 සෙ.මී.)
ඇතුළත් සංරචකFlat surface pH electrode, cap, batteries (pH buffers sold separately)
නිෂ්පාදකයාExtech

8. වගකීම් සහ සහාය

For warranty information, technical support, or to purchase replacement parts and accessories, please visit the official Extech website or contact Extech customer service. You can also find more information and products at the Extech Store on Amazon.

අදාළ ලියකියවිලි - PH90

පෙරview Extech ExStik™ ජල ආරක්ෂිත pH මීටර PH100 ​​සහ PH110 පරිශීලක මාර්ගෝපදේශය
Extech ExStik™ ජල ආරක්ෂිත pH මීටර, PH100 ​​සහ PH110 මාදිලි සඳහා පුළුල් පරිශීලක මාර්ගෝපදේශය. ක්‍රියාකාරිත්වය, ක්‍රමාංකනය, නඩත්තුව සහ පිරිවිතර ගැන ඉගෙන ගන්න.
පෙරview Extech PH220 Waterproof Palm pH Meter User Manual
User manual for the Extech PH220 Waterproof Palm pH Meter. Covers introduction, meter description, operation, calibration, measurement, storage, battery replacement, maintenance, troubleshooting, and specifications.
පෙරview Extech MO257 Pinless Moisture Meter User Guide
User guide for the Extech MO257 Pinless Moisture Meter, detailing its features, operation, specifications, and maintenance for accurate non-invasive moisture measurements in building materials.
පෙරview Extech ET40 බර අඛණ්ඩතා පරීක්ෂක පරිශීලක අත්පොත
Extech ET40 Heavy Duty Continuity Tester සඳහා පරිශීලක අත්පොත. බලගන්වා නොමැති සංරචක, ෆියුස්, ස්විච, රිලේ, රැහැන් සහ පරිපථ පුවරු වල අඛණ්ඩතාව ආරක්ෂිතව සහ ඵලදායී ලෙස පරීක්ෂා කරන්නේ කෙසේදැයි ඉගෙන ගන්න.
පෙරview Extech විද්‍යුත් චුම්භක ක්ෂේත්‍ර මීටර ආකෘතිය 480823 පරිශීලක අත්පොත
Extech විද්‍යුත් චුම්භක ක්ෂේත්‍ර මීටරය, මාදිලිය 480823 සඳහා පරිශීලක අත්පොත. මෙම ලේඛනයේ මීටරයේ පිරිවිතර, ක්‍රියාකාරිත්වය, බැටරි ප්‍රතිස්ථාපනය, EMF නිරාවරණ තොරතුරු, වගකීම් සහ ක්‍රමාංකන සේවා විස්තර කෙරේ. එය 30 සිට 300Hz දක්වා සංඛ්‍යාත කලාප පළලක් සහිත Gauss සහ Tesla ඒකකවල EMF මනිනු ලබයි.
පෙරview Extech ExStik ජල ආරක්ෂිත pH මීටර PH100 ​​සහ PH110 පරිශීලක අත්පොත
Comprehensive user manual for the Extech ExStik Waterproof pH Meters, models PH100 and PH110. Provides detailed instructions on operation, calibration, electrode maintenance, battery replacement, safety precautions, specifications, and troubleshooting for these high-accuracy pH testing devices.