KEITHLEY 2303-PJ

Keithley 2303-PJ Power Supply Instruction Manual

Model: 2303-PJ

1. නිෂ්පාදන අවසන්view

The Keithley 2303-PJ is a specialized power supply designed for testing portable, battery-operated devices. It offers advanced capabilities to simulate a battery's performance across a wide range of conditions, including output resistance and voltage response. This instrument is crucial for accurately testing device charge control circuitry and overall battery simulation.

ප්රධාන ලක්ෂණ ඇතුළත් වේ:

ඉදිරිපස view of the Keithley 2303-PJ Power Supply with display and controls.

Figure 1: Front panel of the Keithley 2303-PJ Power Supply. The display shows voltage and current readings (e.g., 3.60V, 1.08A). Controls include a navigation pad, 'DISPLAY', 'MENU', 'OPERATE', 'ENTER', 'SET' buttons, and a 'POWER' button with indicator lights.

2. පිහිටුවීම

  1. ඉවත් කිරීම සහ පරීක්ෂා කිරීම: Carefully remove the instrument from its packaging. Inspect for any signs of damage during transit. Report any damage to the shipping carrier and Keithley immediately.
  2. බල සම්බන්ධතාවය: Connect the supplied AC power cord to the instrument's rear panel power inlet and then to a grounded AC power outlet. Ensure the power source matches the instrument's voltagඊ අවශ්යතා.
  3. මූලික බලය සක්‍රිය කිරීම: ඔබන්න බලය button located on the front panel. The display should illuminate, indicating the unit is operational.
  4. Connecting to Device Under Test (DUT): Use appropriate test leads to connect the output terminals of the 2303-PJ to the device you intend to test. Observe correct polarity.
  5. වාතාශ්රය: Ensure adequate ventilation around the instrument. Do not block the ventilation grilles on the sides or rear of the unit.

3. මෙහෙයුම් උපදෙස්

3.1 ඉදිරිපස පැනල් පාලන

3.2 මූලික මෙහෙයුම

  1. සැකසීම් වෙළුමtagඊ සහ වත්මන්:
    • ඔබන්න සකසන්න බොත්තම.
    • Use the navigation buttons to select the voltage or current parameter you wish to adjust.
    • Use the navigation buttons (typically Up/Down) to change the value.
    • ඔබන්න ඇතුල් කරන්න සැකසුම තහවුරු කිරීමට.
  2. ප්‍රතිදානය සක්‍රීය කිරීම:
    • Once parameters are set, press the ක්‍රියාත්මක කරන්න button to enable the power output. The output indicator should illuminate.
    • To disable the output, press ක්‍රියාත්මක කරන්න නැවතත්.
  3. අධීක්ෂණ කියවීම්:

    The display continuously shows the actual output voltage and current. Use the දර්ශනය button to cycle through different measurement viewතිබේ නම් s.

4. නඩත්තු කිරීම

5. දෝශ නිරාකරණය

ගැටලුවවිය හැකි හේතුවවිසඳුම
උපකරණය ක්‍රියාත්මක නොවේ.No AC power; faulty power cord; internal fuse blown.Check AC power connection and outlet. Try a different power cord. If fuse is suspected, contact qualified service personnel.
ප්‍රතිදාන වෙළුම නැතtagඉ/ධාරා.Output disabled; incorrect settings; overload protection active; faulty connections.ඔබන්න ක්‍රියාත්මක කරන්න to enable output. Verify voltage/current settings. Check for short circuits or overloads on the DUT. Ensure test leads are securely connected.
Unstable or inaccurate readings.Poor connections; external interference; instrument needs calibration.Check all connections for looseness or corrosion. Ensure the instrument is away from strong electromagnetic fields. Consider professional calibration.
අධික උනුසුම් වීම.Blocked ventilation; excessive ambient temperature; continuous operation at maximum load.Ensure ventilation grilles are clear. Operate in a cooler environment. Reduce load or allow for cool-down periods.

For issues not listed here or if troubleshooting steps do not resolve the problem, please contact Keithley technical support.

6. පිරිවිතර

පරාමිතියවටිනාකම
නිෂ්පාදකයාKeithley
කොටස අංකය2303-PJ
අයිතම ආදර්ශ අංකය2303-PJ
අයිතමයේ බරකිලෝ ග්රෑම් 5.44 කි
පැකේජ මානයන්48.26 x 33.02 x 22.86 සෙ.මී
අයිතම පැකේජ ප්රමාණය1
බැටරි අවශ්‍යද?නැත
පළමු දිනය තිබේ4 නොවැම්බර් 2016

7. වගකීම් සහ සහාය

Warranty information for the Keithley 2303-PJ Power Supply is typically provided with the product at the time of purchase or can be found on the official Keithley webවෙබ් අඩවිය. වගකීම් හිමිකම් සඳහා කරුණාකර ඔබේ මිලදී ගැනීමේ සාක්ෂි තබා ගන්න.

For technical support, service, or calibration inquiries, please contact Keithley customer service directly. Refer to the contact information provided in your product documentation or on the official Keithley webඅඩවිය (www.tek.com/keithley).

අදාළ ලියකියවිලි - 2303-PJ

පෙරview Keithley Models 2302/2302-PJ/2306/2306-PJ/2306-VS Battery/Charger Simulator Instruction Manual
Detailed instruction manual for Keithley Models 2302, 2302-PJ, 2306, 2306-PJ, and 2306-VS Battery/Charger Simulators. Covers operation, safety, measurements, SCPI programming, and specifications for advanced electronic test equipment.
පෙරview Keithley Model 193A System DMM Instruction Manual
Comprehensive instruction manual for the Keithley Model 193A System DMM, detailing its features, specifications, operating procedures, and IEEE-488 programming for precise electronic measurements.
පෙරview Keithley Model 2002 Multimeter Calibration Manual - Procedures and Specifications
Comprehensive calibration manual for the Keithley Model 2002 Multimeter, detailing performance verification, calibration procedures, safety precautions, and technical specifications. Includes IEEE-488 bus commands and programming examples.
පෙරview Keithley 2000/2015/2016/2010 LED Display Replacement Instructions
Step-by-step guide for replacing the VFD display with an LED display on Keithley 2000, 2015, 2016, and 2010 multimeters. Includes disassembly, component replacement, front bezel modification, and reassembly.
පෙරview Measuring Electrical Resistivity of Insulating Materials with Keithley Equipment
Application note detailing how to measure the electrical resistivity of insulating materials using Keithley 6517B Electrometer and 8009 Test Fixture, covering surface and volume resistivity, test methods, and software automation.
පෙරview Keithley Model 7075 General Purpose Multiplexer Card Instruction Manual
This instruction manual details the Keithley Model 7075 General Purpose Multiplexer Card. It covers specifications, operation, applications, safety, and troubleshooting for this test and measurement instrument. Learn more about the Model 7075 from Keithley Instruments.