හැඳින්වීම
This manual provides essential information for the safe installation, operation, and maintenance of your Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light. Please read these instructions thoroughly before installation and use, and retain them for future reference.
The Akicon BPT16-14EL-L12 exhaust fan is designed to effectively remove moisture and odors from bathrooms and similar indoor spaces up to 85 square feet. It features a quiet operation at 1.5 sones and an integrated 12W LED light for illumination.

රූප විස්තරය: ඉදිරිපස පැත්තක්. view of the Akicon BPT16-14EL-L12 bathroom exhaust fan, showcasing its white grille cover with integrated LED light and the metal housing with a black duct connector.
ආරක්ෂිත තොරතුරු
අවවාදයයි: පුද්ගලයන්ට ගින්නක්, විදුලි කම්පනයක් හෝ තුවාල ඇතිවීමේ අවදානම අවම කිරීම සඳහා පහත සඳහන් දෑ නිරීක්ෂණය කරන්න:
- ස්ථාපන කටයුතු සහ විදුලි රැහැන් ඇදීම ගිනි ශ්රේණිගත ඉදිකිරීම් කේත සහ ප්රමිතීන් ඇතුළුව අදාළ සියලුම කේත සහ ප්රමිතීන්ට අනුකූලව සුදුසුකම් ලත් පුද්ගලයා (ය) විසින් සිදු කළ යුතුය.
- ඒකකය රැහැන්ගත කිරීමට හෝ සේවා කිරීමට පෙර සෑම විටම සේවා පැනලයේ විදුලිය විසන්ධි කරන්න.
- This unit is HVI-certified and cUL listed for use over bathtubs and showers when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
- කිසිදු ඝන තත්ත්වයේ වේග පාලන උපකරණයක් සමඟ මෙම විදුලි පංකාව භාවිතා නොකරන්න.
- Never place any object into the fan blades.
- විදුලි පංකාව නිසි ලෙස බිම තබා ඇති බවට වග බලා ගන්න.
- Duct work must be installed with a minimum number of turns and runs to ensure optimal airflow.
පැකේජයේ අන්තර්ගතය
ස්ථාපනය ආරම්භ කිරීමට පෙර සියලුම සංරචක පවතින බව තහවුරු කර ගන්න:
- Exhaust Fan Housing Assembly
- Grille Cover with Integrated LED Light
- 12W E26 Base LED Bulb (pre-installed or separate)
- Installation Hardware (screws, wire connectors)
- පරිශීලක අත්පොත (මෙම ලේඛනය)
පිරිවිතර
| විශේෂාංගය | පිරිවිතර |
|---|---|
| වෙළඳ නාමය | Akicon |
| ආදර්ශ අංකය | BPT16-14EL-L12 |
| වායු ප්රවාහ ධාරිතාව | විනාඩියකට ඝන අඩි 90 (CFM) |
| ශබ්ද මට්ටම | 1.5 සෝන්ස් |
| බලශක්ති ප්රභවය | AC |
| වෙළුමtage | වෝල්ට් 120 |
| LED ආලෝකය Wattage | වොට් 12 |
| LED ආලෝකය වර්ණ උෂ්ණත්වය | 5000K (සීතල සුදු) |
| Housing Dimensions (L x W x H) | 9-3/8" x 9-3/8" x 7-5/16" |
| Grille Cover Size | 11" x 11" |
| නල ප්රමාණය | අඟල් 4 රවුම් |
| නිර්දේශිත කාමර ප්රමාණය | වර්ග අඩි 85 දක්වා |
| සහතික | HVI, cUL Listed |
| අයිතමයේ බර | රාත්තල් 8.83 කි |
සැකසුම සහ ස්ථාපනය
This section outlines the general steps for installing the Akicon BPT16-14EL-L12 exhaust fan. For detailed diagrams and specific instructions, refer to the included installation guide or consult a qualified electrician.
1. පූර්ව-ස්ථාපන සලකා බැලීම්
- Measure Room Size: Ensure the fan's 90 CFM capacity is suitable for your room (up to 85 sq. ft.).
- සිවිලිම විවෘත කිරීම: The recommended ceiling opening size is approximately 9-7/8" x 9-7/8". If replacing an existing fan, measure the current opening. If the existing opening is smaller, it will need to be enlarged to accommodate the new housing.
- නල මාර්ගය: Plan for a 4-inch round duct connection. Use rigid metal ducting for best performance.
- විදුලි රැහැන්: Ensure a 120V AC power supply is available. The fan and light can be wired to operate jointly or separately via wall switches.

රූප විස්තරය: This image displays the critical dimensions for installation. It shows the fan housing size as 9-3/8" x 9-3/8" x 7-5/16", the grille cover size as 11" x 11", and the recommended ceiling opening size as 9-7/8" x 9-7/8". This helps ensure proper fit during installation.

රූප විස්තරය: An installation notice highlighting the housing dimensions (9.4" x 9.4" x 7.7") and emphasizing that the opening hole size should be based on the housing size. It advises checking existing opening sizes for replacements and cutting the hole to match the new housing if necessary.
2. විදුලි පංකා නිවාසය සවි කිරීම
- පරිපථ කඩනයෙහි බලය අක්රිය කරන්න.
- Cut the ceiling opening to the specified dimensions (approx. 9-7/8" x 9-7/8").
- Secure the fan housing to ceiling joists using appropriate fasteners. The housing is designed for screw-in installation. Ensure it is firmly attached to prevent vibration and noise.

රූප විස්තරය: This diagram shows two common installation scenarios: attic and soffit. It illustrates how the fan can be ducted to exhaust air outside, emphasizing the importance of proper ducting for effective ventilation.
3. නල සම්බන්ධතාවය
- Connect a 4-inch round duct to the fan's exhaust collar. Secure with duct tape or clamps.
- Route the duct to an exterior vent cap, ensuring minimal bends and a slight downward slope away from the fan to prevent condensation buildup.

රූප විස්තරය: A comprehensive installation diagram showing the fan housing, duct connection, and electrical wiring points. It provides a visual guide for the step-by-step installation process within a ceiling.
4. විදුලි රැහැන්
- Open the wiring compartment on the fan housing.
- Connect the household wiring to the fan's wiring according to local electrical codes. The fan and light have separate wires, allowing for independent operation if desired (e.g., separate wall switches for fan and light).
- Ensure all connections are secure and properly insulated. Close the wiring compartment cover.
5. Install Grille Cover
- If the LED bulb is not pre-installed, screw the 12W E26 base LED bulb into the socket.
- Attach the grille cover to the fan housing. Typically, this involves inserting mounting springs into slots in the housing and pushing the grille firmly against the ceiling.
Once installation is complete, restore power at the circuit breaker and test the fan and light functions.
මෙහෙයුම් උපදෙස්
The Akicon BPT16-14EL-L12 exhaust fan and LED light are designed for simple operation via standard wall switches.
- විදුලි පංකා මෙහෙයුම: Flip the designated wall switch to turn the exhaust fan ON or OFF.
- සැහැල්ලු මෙහෙයුම: Flip the designated wall switch to turn the LED light ON or OFF.
- If wired separately, the fan and light can be controlled independently. If wired jointly, both will activate simultaneously.
For optimal moisture and odor removal, operate the fan during and after showering or bathing for at least 15-20 minutes.
නඩත්තු කිරීම
Regular maintenance ensures optimal performance and longevity of your exhaust fan. Always disconnect power at the circuit breaker before performing any maintenance.
1. Cleaning the Grille Cover
- Gently pull down the grille cover to detach it from the housing springs.
- Wash the grille cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.

රූප විස්තරය: සවිස්තරාත්මක view of the fan's white grille cover, showing the ventilation slots and the central LED light panel. This component is easily removable for cleaning.
2. Cleaning the Fan Interior
- With the grille removed and power off, carefully wipe down the fan blades and interior of the housing with a damp රෙදි.
- Do not allow water to enter the motor or electrical components.
- විදුලිය යථා තත්ත්වයට පත් කිරීමට පෙර සියලුම කොටස් වියළී ඇති බවට වග බලා ගන්න.
3. LED Bulb Replacement
- විදුලිය විසන්ධි වී ඇති බවට සහතික වන්න.
- Remove the grille cover.
- Unscrew the old E26 base LED bulb and replace it with a new 12W E26 base LED bulb.
- Reattach the grille cover and restore power.
දෝෂගවේෂණය
If you encounter issues with your Akicon exhaust fan, refer to the following common problems and solutions:
| ගැටලුව | විය හැකි හේතුව | විසඳුම |
|---|---|---|
| Fan does not operate / Light does not turn on | No power supply; Loose wiring; Faulty switch; Blown fuse/tripped breaker | Check power at the circuit breaker. Ensure all wiring connections are secure. Test the wall switch. Replace fuse or reset breaker. |
| Fan is excessively noisy | Loose mounting; Obstruction in fan blades; Dirty fan blades/motor; Improper ducting | Ensure fan housing is securely mounted. Disconnect power and check for obstructions. Clean fan blades and motor. Inspect ductwork for kinks or blockages. |
| Poor ventilation performance | Ducting issues (too long, too many bends, wrong size); Blocked exterior vent; Room size exceeds fan capacity | Inspect ductwork for proper installation and clear any blockages. Ensure exterior vent is clear. Verify fan CFM matches room size. |
| LED light flickers or is dim | බුරුල් බල්බය; දෝෂ සහිත බල්බය; රැහැන් ගැටළුව | Ensure bulb is screwed in tightly. Replace the LED bulb. Check electrical connections to the light. |
If the problem persists after attempting these solutions, please contact Akicon customer support.
වගකීම් තොරතුරු
The Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light comes with a වසර 3ක සීමිත වගකීමක් මිලදී ගත් දින සිට. මෙම වගකීම් සහතිකය සාමාන්ය භාවිතය යටතේ ද්රව්ය හා වැඩ කිරීමේ දෝෂ ආවරණය කරයි.
The warranty does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repair or modification. Proof of purchase is required for all warranty claims.
පාරිභෝගික සහාය
For any questions, technical assistance, or warranty claims, please contact Akicon customer service. Have your model number (BPT16-14EL-L12) and proof of purchase ready when contacting support.
Contact information can typically be found on the Akicon official webඅඩවිය හෝ ඔබේ මිලදී ගැනීමේ වේදිකාව හරහා.





