Apera Instruments AI531

Apera Instruments PH820 Benchtop pH Meter Kit

උපදෙස් අත්පොත

නිෂ්පාදනය අවසන්view

The Apera Instruments PH820 Benchtop pH Meter Kit is designed for reliable and accurate pH measurements in laboratory settings. It features advanced functionalities including intelligent calibration, data management, and a durable, water-resistant structure. This manual provides detailed instructions for proper use and care of your PH820 meter.

Apera Instruments PH820 Benchtop pH Meter Kit with electrode and stand

Figure 1: Apera Instruments PH820 Benchtop pH Meter Kit, showing the main unit, electrode, temperature probe, and electrode arm.

Key features of the PH820 include:

සැලසුම

ඇසුරුම් ඉවත් කිරීම සහ සංරචක පරීක්ෂා කිරීම

Carefully unpack all components from the kit. Verify that the following items are present:

සම්බන්ධක සංරචක

Connect the electrode, temperature probe, and power adapter to the corresponding ports on the back of the PH820 meter unit. Ensure all connections are secure.

Back panel of Apera Instruments PH820 pH meter showing connection ports

රූපය 2: පසුපස view of the PH820 meter, highlighting the REF, pH/mV, TEMP, RS232, and DC 9V input ports.

  1. ඉලෙක්ට්රෝඩ සම්බන්ධතාවය: Plug the LabSen 211 pH Electrode into the port labeled "pH/mV".
  2. උෂ්ණත්ව පරීක්ෂණ සම්බන්ධතාවය: Insert the temperature probe into the port labeled "TEMP".
  3. බල සම්බන්ධතාවය: Connect the power adapter to the "DC 9V" port and then to a power outlet.
  4. Electrode Arm Assembly: Attach the flexible electrode arm and holder to the side of the meter unit for convenient electrode placement during measurements.

මෙහෙයුම් උපදෙස්

Basic pH Measurement

  1. බල බොත්තම එබීමෙන් මීටරය ක්‍රියාත්මක කරන්න.
  2. ඉලෙක්ට්‍රෝඩය ආස්රැත ජලයෙන් සෝදා මෘදු ලෙස වියළා ගන්න.
  3. Immerse the electrode and temperature probe into the sample solution. Ensure the electrode tip is fully submerged.
  4. Wait for the reading on the large LCD to stabilize. The meter displays pH and temperature simultaneously.
  5. Record the stable reading.

pH ක්‍රමාංකනය

The PH820 supports 1 to 5 points automatic calibration. Regular calibration ensures measurement accuracy.

  1. Prepare the standard calibration solutions (4.00 pH, 7.00 pH, 10.01 pH are included).
  2. ඔබන්න CAL button to enter calibration mode.
  3. Rinse the electrode and immerse it into the first calibration solution (e.g., 7.00 pH).
  4. The meter will automatically recognize the solution and begin calibration. Wait for the stability icon to appear.
  5. Once stable, the meter will prompt for the next calibration point. Repeat the rinsing and immersion process for subsequent solutions.
  6. The self-diagnosis function will provide feedback on the calibration process and electrode condition, including slope data.
  7. Exit calibration mode once all desired points are completed.

දත්ත කළමනාකරණය

The PH820 allows for GLP data management, storing up to 500 groups of data. Data can be output via USB to a PC using the provided PC-Link software (Windows-based system only). Auto-timing data logging can also be configured.

ORP Measurement (Optional)

The PH820 can measure Oxidation-Reduction Potential (ORP) when an ORP electrode (e.g., 301Pt-C, sold separately) is connected to the pH/mV port. Refer to the ORP electrode's specific instructions for calibration and measurement procedures.

නඩත්තු කිරීම

ඉලෙක්ට්රෝඩ රැකවරණය

Proper care of the LabSen 211 pH Electrode is crucial for maintaining accuracy and extending its lifespan.

Close-up of the LabSen 211 pH electrode

රූපය 3: සමීප රූපය view of the LabSen 211 pH Electrode, showing its glass body and sensor tip.

මීටර සත්කාරය

The PH820 meter unit is IP54 water-resistant, meaning it is protected from dust and splashing water. However, it should not be submerged. Keep the meter clean and dry. Use a soft, damp cloth to wipe the surface. Avoid using abrasive cleaners or solvents.

දෝෂගවේෂණය

The PH820 features a self-diagnosis function that can assist in identifying and fixing common problems, particularly during calibration. Refer to the meter's display for diagnostic messages.

ගැටලුවවිය හැකි හේතුවවිසඳුම
Unstable ReadingsDirty electrode; air bubbles; insufficient sample volume; expired calibration.Clean electrode; ensure no bubbles; use adequate sample; recalibrate.
ක්රමාංකන අසමත් වීමIncorrect buffer solution; contaminated electrode; electrode aging.Use fresh, correct buffers; clean electrode; check electrode slope data (self-diagnosis) for replacement indication.
No Display/PowerPower adapter issue; loose connection.Check power adapter and outlet; ensure all cables are securely connected.
වැරදි කියවීම්Electrode not calibrated; temperature not compensated; damaged electrode.Perform calibration; ensure temperature probe is functioning; inspect electrode for damage.

For persistent issues not resolved by the above, please contact Apera Instruments customer support.

පිරිවිතර

පරාමිතියවටිනාකම
ආදර්ශ අංකයAI531
pH නිරවද්‍යතාවය±0.002 pH±1 digit
ක්රමාංකන ලකුණු1 to 5 points (Auto.)
දත්ත ගබඩා කිරීම500 groups (GLP compliant)
දත්ත ප්රතිදානයUSB (PC software support)
ජල ප්රතිරෝධයIP54
බල ආදානය120V ඒසී 60Hz
බලශක්ති ප්රතිදානය9V 300mA
පැකේජ මානයන්අඟල් 10.67 x 10.2 x 6.65
බරපවුම් 6.69ක්
සහතිකCE, RoHS, ISO 9001:2015

වගකීම් සහ සහාය

Apera Instruments products are manufactured under an ISO 9001:2015 certified quality system, ensuring high standards of production. For specific warranty information and technical support, please refer to the warranty card included with your product or visit the official Apera Instruments website. You may also contact their customer service directly for assistance with product operation, troubleshooting, or parts replacement.

අදාළ ලියකියවිලි - AI531

පෙරview Apera PH60Z-WW Smart pH Meter User Manual
Comprehensive user manual for the Apera PH60Z-WW Smart pH Meter, covering setup, calibration, measurement, troubleshooting, and specifications for wastewater, suspensions, and emulsions.
පෙරview PH60Z-HT Smart pH Meter User Manual - Apera Instruments
User manual for the Apera Instruments PH60Z-HT Smart pH Meter, detailing its features, operation, calibration, maintenance, and troubleshooting for high temperature and caustic solutions.
පෙරview Apera SX811-SS Portable pH Meter for Food Testing: Instruction Manual & Specifications
Comprehensive instruction manual and technical specifications for the Apera SX811-SS portable pH meter, designed for accurate food testing. Learn about features, calibration, setup, USB communication, and troubleshooting.
පෙරview Apera PH60Z-MS Smart pH-Meter: Bedienungsanleitung für Kleinvolumenmessungen
Diese Bedienungsanleitung bietet detaillierte Informationen zur Verwendung des Apera PH60Z-MS Smart pH-Meters, einschließlich Kalibrierung, Messung, Wartung und Fehlerbehebung für präzise pH-Messungen in kleinen Volumina.
පෙරview Apera PH60-HT pH Meter User Manual: High Temperature & Caustic Solutions
Comprehensive user manual for the Apera PH60-HT pH Meter, designed for accurate pH measurement in high temperature (up to 140°C) and caustic solutions. Covers kit contents, operation, calibration, electrode care, parameter settings, technical specifications, troubleshooting, and warranty.
පෙරview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instruction manual for the Apera PH700 Benchtop pH Meter, covering features, specifications, operation, calibration, maintenance, and troubleshooting.