CQR B07WWCXZC9

CQR Hold-up PA Double Push Panic Button User Manual

Model: B07WWCXZC9

1. හැඳින්වීම

මෙම අත්පොත ස්ථාපනය, ක්‍රියාත්මක කිරීම සහ නඩත්තු කිරීම සඳහා සවිස්තරාත්මක උපදෙස් සපයයි CQR Hold-up PA Double Push Panic Button. This device is designed to provide a reliable and immediate alert in emergency situations, integrating seamlessly with compatible alarm control panels. It features a double-press activation mechanism and a key-reset function to prevent accidental activation and ensure secure operation.

නිසි ක්‍රියාකාරීත්වය සහ ආරක්ෂාව සහතික කිරීම සඳහා ස්ථාපනය කිරීමට පෙර කරුණාකර මෙම අත්පොත හොඳින් කියවා භාවිතා කරන්න.

2 ආරක්ෂිත තොරතුරු

  • විදුලි ආරක්ෂාව: Installation should only be performed by qualified personnel in accordance with all local and national electrical codes. Ensure power to the alarm control panel is disconnected before wiring.
  • සවි කිරීම: Mount the device securely on a stable surface to prevent accidental dislodgement.
  • පරිසරය: Do not expose the device to extreme temperatures, humidity, or direct water. It is designed for indoor use only.
  • නඩත්තු: Do not attempt to open or repair the device yourself. Refer all servicing to qualified service personnel.
  • පරීක්ෂා කිරීම: Regularly test the panic button's functionality in conjunction with your alarm system to ensure it is operating correctly.

3. පැකේජ අන්තර්ගතය

පහත ලැයිස්තුගත කර ඇති සියලුම අයිතම ඔබේ පැකේජයේ ඇති බව තහවුරු කරගන්න:

  • CQR Hold-up PA Double Push Panic Button Unit
  • Key for Reset Function
  • Mounting Screws (may vary)
  • මෙම පරිශීලක අත්පොත
CQR Hold-up PA Double Push Panic Button with key
Figure 3.1: The CQR Hold-up PA Double Push Panic Button, showing the two red push buttons, the keyhole for reset, and the included black reset key.
Close-up of the panic button reset key
රූපය 3.2: සමීප රූපයක් view of the metallic key used to reset the panic button after activation.
Product packaging for CQR Double Push PA
Figure 3.3: The product packaging, displaying the "DOUBLE PUSH PA" label and a barcode.

4. පිහිටුවීම සහ ස්ථාපනය

The CQR Hold-up PA Double Push Panic Button is designed for surface mounting and integration with a compatible alarm control panel.

4.1. සවිකරන ස්ථානය

Choose a discreet yet easily accessible location for mounting, such as under a counter, desk, or near a point of sale. Ensure the surface is clean, dry, and structurally sound.

4.2. Wiring to Alarm Control Panel

  1. බලය විසන්ධි කරන්න: Before beginning any wiring, ensure the alarm control panel is completely powered off and disconnected from its main power source and backup battery.
  2. Access Wiring Terminals: ඇ විවෘත කරන්නasing of the panic button (if applicable) to expose the wiring terminals. Refer to your alarm control panel's manual for specific zone input terminals for panic devices.
  3. සම්බන්ධක වයර්: Connect the panic button's output wires to the designated panic zone input terminals on your alarm control panel. This device typically operates as a Normally Closed (NC) contact, opening upon activation. Consult the wiring diagram provided with your alarm control panel for correct polarity and connection points.
  4. ආරක්ෂිත රැහැන්: සියලුම වයර් සම්බන්ධතා ආරක්ෂිතව සහ නිසි ලෙස පරිවරණය කර ඇති බවට සහතික වන්න.
  5. C වසන්නasing: Carefully close the panic button casing.

4.3. ඒකකය සවි කිරීම

  1. සලකුණු සිදුරු: Use the panic button unit as a template to mark the drilling locations for the mounting screws on your chosen surface.
  2. සරඹ නියමු සිදුරු: Drill pilot holes if necessary, appropriate for the mounting screws.
  3. ආරක්ෂිත උපාංගය: Align the panic button with the drilled holes and secure it firmly using the provided mounting screws. Do not overtighten.

4.4. Power On and Test

Once installation is complete, restore power to the alarm control panel. Perform a functional test of the panic button as described in the "Operating Instructions" section to ensure it triggers the alarm system correctly.

5. මෙහෙයුම් උපදෙස්

5.1. Activating the Panic Button

To activate the panic alarm, simultaneously press both red push buttons on the front of the unit. The double-press mechanism is designed to minimize accidental activations while ensuring quick response in an emergency.

Upon successful activation, the panic button will latch, and the alarm control panel will initiate the programmed panic response (e.g., siren activation, silent alarm, notification to monitoring station).

5.2. Resetting the Panic Button

After activation, the panic button will remain in a latched state until manually reset. To reset the device:

  1. Insert the provided key into the keyhole located on the top surface of the panic button.
  2. Turn the key clockwise (or counter-clockwise, depending on the specific mechanism) until the buttons release and return to their original position.
  3. Remove the key. The panic button is now reset and ready for re-activation.

වැදගත්: Always keep the reset key in a secure and accessible location known only to authorized personnel.

6. නඩත්තු කිරීම

The CQR Hold-up PA Double Push Panic Button requires minimal maintenance to ensure reliable operation.

  • පිරිසිදු කිරීම: Periodically wipe the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture.
  • පරීක්ෂා කිරීම: It is recommended to test the panic button's functionality at least once a month to confirm its connection to the alarm system and proper activation/reset.
  • පරීක්ෂාව: Visually inspect the unit for any signs of damage, loose wiring, or tampering.

7. දෝශ නිරාකරණය

If you encounter issues with your CQR Hold-up PA Double Push Panic Button, refer to the following common problems and solutions:

ගැටලුවවිය හැකි හේතුවවිසඳුම
Panic button does not activate alarm.
  • Incorrect wiring to alarm panel.
  • ලිහිල් වයර් සම්බන්ධතා.
  • Alarm panel zone not properly configured.
  • උපාංගයේ අක්රිය වීම.
  • Verify wiring against alarm panel manual.
  • සියලුම වයර් සම්බන්ධතා පරීක්ෂා කර සුරක්ෂිත කරන්න.
  • Consult alarm panel manual for zone programming.
  • Contact qualified service personnel if issue persists.
Panic button does not reset with key.
  • Key not fully inserted or turned correctly.
  • අභ්‍යන්තර යාන්ත්‍රණයට බාධාවක් හෝ හානියක්.
  • Ensure key is fully inserted and turned firmly.
  • Do not force the key. If still stuck, contact service personnel.
Accidental activations.
  • Improper mounting location.
  • භෞතික බාධා.
  • Relocate the device to a less prone area.
  • Ensure no objects are pressing against the buttons.

If the problem persists after attempting these solutions, please contact your alarm system installer or the manufacturer's technical support.

8. පිරිවිතර

විශේෂාංගයවිස්තර
ආකෘතියHold-up PA Double Push
ASINB07WWCXZC9
වෙළඳ නාමයCQR
නිෂ්පාදකයාSecurity Components LTD
වර්ණයසුදු
සක්රිය කිරීමේ වර්ගයDouble Press Latching
Reset Mechanismයතුරු යළි පිහිටුවීම
ගැළපුමUniversal operation with Alarm control panel
පළමු දිනය තිබේ22 අගෝස්තු 2019

9. වගකීම් සහ සහාය

Specific warranty information for the CQR Hold-up PA Double Push Panic Button is not provided within this manual. For details regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact the retailer or manufacturer directly.

For technical support, installation assistance, or troubleshooting beyond the scope of this manual, please contact your alarm system installer or the manufacturer, Security Components LTD, through their official channels.

You can visit the CQR Store on Amazon for more information: CQR Store

අදාළ ලියකියවිලි - B07WWCXZC9

පෙරview CQR Panic Buttons: Understanding and Specifications
විස්තීර්ණ ඉවරයිview of CQR panic buttons, detailing types, features, security grades, and technical specifications for domestic and commercial applications.
පෙරview CQR Panic Buttons: Understanding and Product Specifications
A comprehensive guide to CQR panic buttons, detailing their functionality, types (mechanical, electronic, single/double push, confirmed), reset methods, fitting options, and finishes. Includes detailed product specifications and comparisons for the PASP, PADP, and EPA ranges.
පෙරview CQR FP3 Manual Call Point & Security Devices | Technical Overview
සවිස්තරාත්මක තාක්ෂණික විස්තරයview of CQR's FP3 Manual Call Point, featuring single and double pole configurations, EN54-11 certification, and other security products including Personal Attack Buttons, FP2 Call Points, Junction Boxes, and Empty Boxes.
පෙරview CQR PADP3 Series Hold-up Device: Operating and Installation Instructions
Comprehensive guide to installing and operating the CQR PADP3 Series hold-up device, covering setup, specifications, and features for security systems.
පෙරview CQR PADP2 Grade 1: Double Push Hold Up Device | Security Solutions
Explore the CQR PADP2 Grade 1 Double Push Hold Up Device. This brochure details its features, technical specifications, product codes, and compliance with PD6662:2010 for reliable security applications.
පෙරview CQR Security Intruder Detection Systems Product Catalog
Comprehensive product catalog from CQR Security detailing intruder detection systems, including a wide range of cables, magnetic contacts, sounders, shock sensors, hold-up devices, call points, power supplies, junction boxes, exit buttons, and 12V fire detectors for security applications.