BFT P125002

BFT SB-BAT P125002 24V DC බැටරි උපස්ථ කට්ටල උපදෙස් අත්පොත

For BFT Gate Opener Systems

1. හැඳින්වීම

This manual provides essential instructions for the installation, operation, and maintenance of the BFT SB-BAT P125002 24V DC Battery Backup Kit. This kit is designed to ensure continuous operation of compatible BFT gate openers during temporary power outages. Please read this manual thoroughly before proceeding with installation or use.

2. නිෂ්පාදන අවසන්view

The BFT SB-BAT P125002 is a 24V DC battery backup system that integrates with specific BFT gate operators. It includes a smart charger board that manages battery charging when main power is available and automatically switches to battery power when the main supply is interrupted.

BFT SB-BAT P125002 Battery Backup Kit components in box

රූපය 1: අවසන්view of the BFT SB-BAT P125002 Battery Backup Kit, showing the product box, two batteries, wiring, and mounting hardware.

2.1 කට්ටල සංරචක

Individual components of the BFT SB-BAT P125002 Battery Backup Kit

රූපය 2: සවිස්තරාත්මක view of the BFT SB-BAT P125002 kit components, including batteries, wiring, mounting brackets, and the battery holder.

3. ගැළපුම

This battery backup system is compatible with the following BFT gate operator series:

Ensure your gate operator model is listed above for proper functionality.

4. පිහිටුවීම සහ ස්ථාපනය

Installation of the BFT SB-BAT P125002 kit is designed to be straightforward. However, it is recommended that installation be performed by a qualified technician to ensure safety and correct operation. Always disconnect main power to the gate operator before beginning installation.

4.1. ආරක්ෂිත පූර්වාරක්ෂාවන්

4.2. ස්ථාපන පියවර (සාමාන්‍ය මාර්ගෝපදේශ)

  1. Mount the Battery Holder: Secure the battery holder/mounting base within the gate operator's control box or an appropriate enclosure using the provided mounting brackets and fasteners. Ensure it is stable and accessible.
  2. බැටරි ඇතුළු කරන්න: Place the two 12V 1.2Ah batteries into the battery holder.
  3. බැටරි සම්බන්ධ කරන්න: Connect the batteries in series to achieve 24V DC, following the wiring diagram provided with your specific gate operator or the kit's smart charger board. Ensure correct polarity.
  4. Connect Smart Charger Board: Integrate the smart charger board into the gate operator's control unit. Refer to your gate operator's manual for the specific connection points for the battery backup system.
  5. ආරක්ෂිත රැහැන්: Route and secure all wiring to prevent pinching or damage.
  6. බලය ප්‍රතිස්ථාපනය කරන්න: Once all connections are verified and secure, restore main power to the gate operator. The smart charger board will begin charging the batteries.
  7. පරීක්ෂණ පද්ධතිය: Perform a power outage simulation to verify the battery backup system activates correctly and powers the gate operator.

5. මෙහෙයුම් උපදෙස්

The BFT SB-BAT P125002 operates automatically once installed correctly.

5.1. Normal Operation (Power On)

When main power is supplied to the gate operator, the smart charger board within the SB-BAT kit continuously monitors the battery charge level. It will charge the batteries as needed to maintain them at full capacity.

5.2. බලය ඕtage Operation (Power Off)

බලයක් ඇති අවස්ථාවක outage, the smart charger board automatically detects the loss of main power and switches the gate operator to battery power. The gate operator will then function normally using the stored energy in the batteries. The duration of operation on battery power depends on the frequency of gate usage and the charge level of the batteries.

6. නඩත්තු කිරීම

Regular maintenance ensures the longevity and reliability of your battery backup system.

6.1. Battery Recharging

බලයකින් පසු outage, once main power is restored, the smart charger board will automatically begin recharging the batteries. A full recharge typically takes පැය 12 සිට 14 දක්වා. It is important to allow sufficient time for batteries to fully recharge after use.

6.2. Fuse Check

පද්ධතියට ඇතුළත් වේ 20 ෆියුස් for protection. If the battery backup system fails to operate or charge, inspect the fuse for continuity. Replace with a fuse of the exact same rating if necessary. Always disconnect power before checking or replacing fuses.

6.3. බැටරි ආයු කාලය සහ ප්‍රතිස්ථාපනය

Batteries have a finite lifespan. Periodically test the system by simulating a power outage to ensure batteries hold a charge and can power the gate operator. If performance degrades significantly, consider replacing the batteries. Use only recommended replacement batteries (2x 12V 1.2Ah sealed lead-acid).

7. දෝශ නිරාකරණය

If your BFT SB-BAT P125002 battery backup system is not functioning as expected, consider the following:

For persistent issues, contact BFT technical support or a qualified service technician.

8. පිරිවිතර

විශේෂාංගයපිරිවිතර
ආදර්ශ අංකයP125002
බැටරි වර්ගයමුද්රා තැබූ ඊයම්-ඇසිඩ්
බැටරි ධාරිතාව2x (12V 1.2Ah)
ප්රතිදාන වෙළුමtage24V DC (nominal)
ගාස්තුව වෙළුමtage27.2V
ආරෝපණ ධාරාව130mA
බැටරි නැවත ආරෝපණය කිරීමේ කාලයපැය 12-14
Exhausted Battery Protection Threshold20.4V
ෆියුස් ශ්‍රේණිගත කිරීම20A
මෙහෙයුම් උෂ්ණත්වයData detected with external temperature of: 25°C (77°F)

9. වගකීම් සහ සහාය

For warranty information, please refer to the documentation provided with your original purchase or contact BFT customer support directly. For technical assistance, installation queries, or troubleshooting beyond the scope of this manual, please contact your authorized BFT dealer or BFT technical support.

BFT Contact Information: Please visit the official BFT webවඩාත්ම යාවත්කාලීන සම්බන්ධතා තොරතුරු සහ සහාය සම්පත් සඳහා අඩවිය.

අදාළ ලියකියවිලි - P125002

පෙරview BFT DEIMOS BT UL/CSA Electromechanical Gate Automation System
Discover the BFT DEIMOS BT UL/CSA, an electromechanical automation system for rack sliding gates. Featuring smart technology, 24V safe operation, and simplified installation, this system enhances gate security and convenience. Explore its technical specifications and available accessories for residential and commercial applications.
පෙරview BFT Mitto 2M/4M දුරස්ථ කේතීකරණ උපදෙස්: පුළුල් මාර්ගෝපදේශයකි
ගරාජ් සහ ගේට්ටු විවෘත කරන්නන් සඳහා ඔබේ BFT Mitto 2M සහ 4M දුරස්ථ පාලක ක්‍රමලේඛනය කරන්නේ කෙසේදැයි ඉගෙන ගන්න. මෙම මාර්ගෝපදේශය වැදගත් ආරක්ෂක අනතුරු ඇඟවීම් ඇතුළුව ඩිජිටල් තිර සහිත සහ රහිත ග්‍රාහක සඳහා කේතනය ආවරණය කරයි.
පෙරview BFT VIRGO Swing Gate Automation Installation Manual
Comprehensive installation and user guide for the BFT VIRGO swing gate automation system, covering safety, technical specifications, installation procedures, programming, and maintenance.
පෙරview Manuale di Installazione e Uso BFT GIOTTO 30-60 S BT / GIOTTO 30-60 BT
GIOTTO 30-60 S BT e GIOTTO 30-60 BT ස්වයංක්‍රීයව ස්වයංක්‍රීයව ස්වයංක්‍රීය කිරීම සඳහා Guida සම්පූර්ණයි. Specifiche techniche, configurazione e manutenzione ඇතුළත් කරන්න.
පෙරview BFT MITTO 2B දුරස්ථ කේතීකරණ උපදෙස් | රෙට්රෝ දුරස්ථ පාලක
ගේට්ටු විවෘත කරන්නන් සඳහා BFT MITTO 2B දුරස්ථ පාලක කේතනය කිරීම සඳහා පියවරෙන් පියවර මාර්ගෝපදේශය, පවතින දුරස්ථ පාලක සහ ග්‍රාහක LCD තිර ක්‍රම ආවරණය කරයි. දෝශ නිරාකරණ උපදෙස් ඇතුළත් වේ.
පෙරview BFT CLONIX1-2 සහ MITTO 2-4 433MHz රේඩියෝ පාලන පද්ධති ස්ථාපන මාර්ගෝපදේශය
BFT CLONIX1-2 ග්‍රාහකය සහ MITTO 2-4 433MHz රේඩියෝ පාලන සම්ප්‍රේෂක සඳහා වන සවිස්තරාත්මක ස්ථාපන මාර්ගෝපදේශය, ගේට්ටු සහ දොර ස්වයංක්‍රීයකරණය සඳහා ක්‍රමලේඛනය, ක්ලෝනකරණය, ආරක්ෂාව සහ තාක්ෂණික පිරිවිතර ආවරණය කරයි.