1. හැඳින්වීම
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Eaton CHPSURGE Plug-On Neutral Surge Protective Device (SPD). This Type 2 SPD is designed to protect your home's electrical system and connected equipment from damaging power surges. Please read this manual thoroughly before installation or use.
2 ආරක්ෂිත තොරතුරු
අවවාදයයි: Risk of electric shock. Installation and servicing of this device must be performed by qualified electrical personnel only. Failure to follow these instructions may result in serious injury or death.
- Always disconnect power at the main service panel before installing or servicing the surge protective device.
- vol එකක් භාවිතයෙන් බලය විසන්ධි වී ඇති බව තහවුරු කරන්නtagඉදිරියට යාමට පෙර ඊ පරීක්ෂක.
- ස්ථාපනය අතරතුර සියලුම දේශීය සහ ජාතික විදුලි කේත අනුගමනය කරන බවට සහතික වන්න.
- Do not install this device in a wet or damp ස්ථානය.
3. නිෂ්පාදන අවසන්view
The Eaton CHPSURGE is a 2-pole, plug-on neutral surge protective device designed for use in Eaton CH series load centers. It provides whole-home surge protection by diverting harmful transient voltages away from sensitive electronics. The device features a green LED indicator to confirm operational status.

රූපය 1: ඉදිරිපස view of the Eaton CHPSURGE device. This image shows the compact, black housing of the surge protective device, with the Eaton logo and 'SURGE PROTECTOR' label visible. A green indicator light is present, labeled 'PROTECTED WHEN LIT', signifying operational status. The model number 'CHPSURGE' is also clearly displayed.

Image 2: Eaton CHPSURGE device alongside its retail packaging. The packaging displays the Eaton logo, 'CHPSURGE', 'QTY. 1', and 'SURGE-PROTECTIVE DEVICE TYPE 2', along with voltage ratings '120 / 240 V~' and '2 POLE'. A barcode with the number 786689353674 is also visible.
4. සැකසුම (ස්ථාපනය)
The Eaton CHPSURGE is a permanently connected device designed for installation within a compatible Eaton CH series load center. It is installed on the load side of the service entrance overcurrent protective device.
- විදුලිය විසන්ධි කිරීම: Locate your main electrical panel and turn off the main breaker to completely de-energize the panel. Verify power is off using a voltagඊ පරීක්ෂක.
- පැනල් ප්රවේශය: Carefully remove the cover of your electrical panel.
- උපාංගය ස්ථානගත කිරීම: Identify two adjacent available spaces in your Eaton CH series load center. The CHPSURGE device is a 2-pole breaker form factor.
- ස්ථාපනය: Insert the CHPSURGE device into the two available breaker slots. Ensure it is firmly seated on the bus bar. The plug-on neutral feature simplifies connection to the neutral bus.
- රැහැන් ඇදීම: Connect the neutral wire from the surge protective device to the neutral bus bar in the panel. Connect the ground wire to the ground bus bar. Ensure all connections are tight and secure.
- පැනල වැසීම: Replace the electrical panel cover, ensuring all wires are clear of the cover and screws.
- බල පුනස්ථාපනය: Turn the main breaker back on. The green LED indicator on the CHPSURGE device should illuminate, indicating it is operational and providing protection.
5. ක්රියාත්මක වීම
Once properly installed and power is restored, the Eaton CHPSURGE device operates continuously to protect your electrical system. The green LED indicator on the front of the device signifies that the surge protection is active and functioning correctly. The device automatically detects and diverts harmful voltage surges, protecting your home's electrical circuits and connected appliances.
6. නඩත්තු කිරීම
The Eaton CHPSURGE device requires minimal maintenance. Periodically check the green LED indicator on the front of the device. As long as the LED is illuminated, the device is providing surge protection.
- LED දර්ශක පරීක්ෂාව: Visually inspect the device's LED indicator at least once a month.
- Device Replacement: If the green LED indicator is off, it signifies that the device has absorbed a significant surge event and is no longer providing protection. The device must be replaced immediately to restore surge protection.
7. දෝශ නිරාකරණය
| ගැටලුව | විය හැකි හේතුව | විසඳුම |
|---|---|---|
| Green LED indicator is off. | The device has absorbed a surge and is no longer functional. | Replace the Eaton CHPSURGE device with a new one. |
| No power to the panel after installation. | Main breaker is off or tripped. | Ensure the main breaker in your electrical panel is in the 'ON' position. If it tripped, reset it. |
| Device does not fit in panel. | Incorrect panel type. | This device is designed for Eaton CH series panels only. Verify your panel type. Do not attempt to force installation into incompatible panels. |
8. පිරිවිතර
- නිෂ්පාදන වර්ගය: Type CH Circuit Breaker Surge Protective Device
- පොලු: දෙකක් ධ්රැවය
- සම්බන්ධතා වර්ගය: ප්ලග්-ඔන් උදාසීන
- Surge Protection Type: 2 SPD වර්ගය
- කෙටි පරිපථ ශ්රේණිගත කිරීම: 10 kA
- බාධා කිරීම් ඇගයීම: 10 kAIC
- සංඛ්යාත ශ්රේණිගත කිරීම: 50/60 Hz
- Surge Current: 18 kA
- උපරිම අඛණ්ඩ මෙහෙයුම් පරිමාවtage (MCOV): 150 V LN, 300 V LL
- වෙළුමtage: වෝල්ට් 240
- සහතික: UL 1449 3rd Edition Listed
- නිෂ්පාදන මානයන්: ආසන්න වශයෙන් 7 x 4 x 0.01 අඟල්
- අයිතමයේ බර: ආසන්න වශයෙන් 7 අවුන්ස
9. වගකීම් සහ සහාය
Eaton products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the documentation included with your purchase or visit the official Eaton webඅඩවිය.
For technical assistance, troubleshooting beyond the scope of this manual, or to inquire about replacement parts, please contact Eaton customer support. Have your product model number (CHPSURGE) and purchase information ready when contacting support.
ඊටන් නිල Webඅඩවිය: www.eaton.com