1. හැඳින්වීම
The DIGITEN TTC-1003 is a versatile 3-stage outlet temperature controller designed for precise environmental management. It features two temperature-controlled outlets and one timer-controlled outlet, allowing for independent regulation of heating, cooling, and lighting cycles. This device is suitable for a wide range of applications, including reptile habitats, incubators, greenhouses, mushroom cultivation, and home brewing. This manual provides detailed instructions for the safe and effective operation of your TTC-1003 controller.

Figure 1: DIGITEN TTC-1003 Temperature Controller
2 ආරක්ෂිත තොරතුරු
Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product.
- බල සැපයුම් පරිමාව සහතික කරන්නtage matches the specifications of the controller (100-240V AC).
- Do not immerse the main controller unit in water or expose it to excessive moisture. The temperature probes are waterproof, but the main unit is not.
- පිරිසිදු කිරීමට හෝ නඩත්තු කිරීමට පෙර සෑම විටම උපාංගය විදුලිබල පද්ධතියෙන් විසන්ධි කරන්න.
- Do not exceed the maximum rated current of 15A for the entire unit.
- උපාංගය ළමයින්ට සහ සුරතල් සතුන්ට ළඟාවිය නොහැකි ලෙස තබා ගන්න.
- Do not disassemble or modify the controller. Refer all servicing to qualified personnel.
- Ensure all connected appliances are in good working condition and do not exceed the controller's wattagඊ සීමාවන්.
3. නිෂ්පාදන අවසන්view
3.1 සංරචක
- DIGITEN TTC-1003 Controller Unit
- 2 x Temperature Sensor Probes (2m / 78.74in each)
- Power Cord (1.4m / 55.12in)
3.2 ප්රධාන ලක්ෂණ
- භාවිතයට පහසු: Plug-and-play design with a large LCD display.
- ස්වාධීන පාලනය: Two temperature-controlled outlets (OUT1, OUT2) and one timer-controlled outlet (OUT3) operate independently.
- පුළුල් උෂ්ණත්ව පරාසය: Regulates and maintains temperatures from 14°F to 248°F (-10°C to 120°C).
- Dual Sensor Probes: Two probes for reliable temperature tracking.
- Day/Night Temperature Control: Allows for different temperature settings for day and night cycles on temperature-controlled outlets.
- කාල කාර්යය: Outlet 3 offers a time cycle function for lighting or other timed devices.
- මතක කාර්යය: All settings are saved in the event of a power outage.
- උෂ්ණත්ව ඒකක ස්විචය: සෙල්සියස් (°C) සහ ෆැරන්හයිට් (°F) අතර පහසුවෙන් මාරු වන්න.
- ඉහළ/අඩු උෂ්ණත්ව එලාමය: Provides alerts for temperature deviations.

Figure 2: Key Features of the TTC-1003
4. සැකසුම් උපදෙස්
4.1 මූලික ස්ථානගත කිරීම
- Choose a dry, stable location for the controller unit, away from direct sunlight or heat sources.
- The unit can be wall-mounted using the integrated hanging slot on the back.

Figure 3: Wall-Mounted Installation
4.2 Connecting Probes and Devices
- Plug the two temperature sensor probes into the designated ports on the top of the controller.
- Position the sensor probes in the environment where temperature monitoring is required. Ensure they are not directly exposed to heating elements or water if not intended.
- Plug your heating or cooling devices into OUT1 and OUT2. These outlets are temperature-controlled.
- Plug your lighting or other timed devices into OUT3. This outlet is timer-controlled.
- Plug the controller's power cord into a standard electrical outlet. The LCD display will illuminate.

රූපය 4: උදාample Applications and Connections
5. මෙහෙයුම් උපදෙස්
The controller features a large LCD display and three buttons: සකසන්න, ඔරලෝසුව, සහ ඉහළ/පහළ ඊතල.
5.1 වත්මන් වේලාව සැකසීම
- ඔබා අල්ලාගෙන සිටින්න ඔරලෝසුව button for 3 seconds until the hour digit flashes.
- භාවිතා කරන්න ඉහළ/පහළ ඊතල පැය සකස් කිරීමට.
- ඔබන්න ඔරලෝසුව again to move to the minute digit, then adjust with ඉහළ/පහළ ඊතල.
- ඔබන්න ඔරලෝසුව තහවුරු කිරීමට සහ පිටවීමට.
5.2 Temperature Control (Outlets 1 & 2)
Outlets 1 and 2 are independently controlled for temperature. Each can be set for heating or cooling mode with specific ON/OFF temperatures and operating times.
- ඔබා අල්ලාගෙන සිටින්න සකසන්න button for 3 seconds to enter programming mode. The display will show 'OUT1' or 'OUT2' and the first setting will flash.
- භාවිතා කරන්න ඉහළ/පහළ ඊතල to select 'OUT1' or 'OUT2'. Press සකසන්න තහවුරු කිරීමට.
- වේලාව සකසන්න: The 'ON' time will flash. Use ඉහළ/පහළ ඊතල පැය සැකසීමට, පසුව ඔබන්න සකසන්න to set minutes. This is the time when temperature control for this outlet begins.
- අක්රිය වේලාව සකසන්න: The 'OFF' time will flash. Use ඉහළ/පහළ ඊතල පැය සැකසීමට, පසුව ඔබන්න සකසන්න to set minutes. This is the time when temperature control for this outlet ends.
- Set ON Temperature: The 'ON Temp' will flash. Use ඉහළ/පහළ ඊතල to set the temperature at which the connected device turns ON.
- Set OFF Temperature: The 'OFF Temp' will flash. Use ඉහළ/පහළ ඊතල to set the temperature at which the connected device turns OFF.
- Determine Mode (Heating/Cooling):
- If ON Temp < OFF Temp: The controller operates in තාපන මාදිලිය. The device turns on when the temperature drops to ON Temp and turns off when it reaches OFF Temp.
- If ON Temp > OFF Temp: The controller operates in සිසිලන මාදිලිය. The device turns on when the temperature rises to ON Temp and turns off when it reaches OFF Temp.
- ඔබන්න සකසන්න to cycle through additional settings (High Alarm, Low Alarm, Calibration) or press ඔරලෝසුව සුරැකීමට සහ පිටවීමට.

Figure 5: Temperature Control Programming Example
5.3 Timer Control (Outlet 3)
Outlet 3 operates as a simple timer, allowing for two independent ON/OFF periods within a 24-hour cycle.
- ඔබා අල්ලාගෙන සිටින්න සකසන්න button for 3 seconds to enter programming mode.
- භාවිතා කරන්න ඉහළ/පහළ ඊතල to select 'OUT3'. Press සකසන්න තහවුරු කිරීමට.
- Set First ON Time: The 'ON' time for the first period will flash. Adjust with ඉහළ/පහළ ඊතල සහ තහවුරු කරන්න සකසන්න.
- Set First OFF Time: The 'OFF' time for the first period will flash. Adjust with ඉහළ/පහළ ඊතල සහ තහවුරු කරන්න සකසන්න.
- සඳහා පියවර නැවත කරන්න Second ON Time සහ Second OFF Time if a second timed period is desired. If not, set the second ON time to be the same as the second OFF time to disable it.
- ඔබන්න ඔරලෝසුව සුරැකීමට සහ පිටවීමට.

Figure 6: Timer Control Programming Example for Outlet 3
5.4 උෂ්ණත්ව ඒකක තේරීම (°C/°F)
To switch between Celsius and Fahrenheit, briefly press the UP ඊතලය button while in normal operating mode.
5.5 High/Low Temperature Alarms (AH/AL)
You can set high and low temperature alarms for Outlets 1 and 2 to be notified if the temperature goes outside your desired range.
- Enter programming mode for OUT1 or OUT2 (as described in 5.2).
- After setting ON/OFF temperatures, press සකසන්න until 'AH' (High Alarm) flashes. Use ඉහළ/පහළ ඊතල to set the desired high temperature limit.
- ඔබන්න සකසන්න until 'AL' (Low Alarm) flashes. Use ඉහළ/පහළ ඊතල to set the desired low temperature limit.
- ඔබන්න ඔරලෝසුව සුරැකීමට සහ පිටවීමට.
6. නඩත්තු කිරීම
Regular maintenance ensures the longevity and accuracy of your DIGITEN TTC-1003 controller.
- පිරිසිදු කිරීම: Wipe the controller unit with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the unit is unplugged before cleaning.
- පරීක්ෂණ සත්කාර: Periodically inspect the temperature probes for any signs of damage or wear. Ensure the probes are clean for accurate readings. The probes are waterproof and can be cleaned with a damp රෙදි.
- ගබඩා: If storing the device for an extended period, unplug it and store it in a cool, dry place.

Figure 7: Waterproof Temperature Probe
7. දෝශ නිරාකරණය
If you encounter issues with your controller, refer to the table below for common problems and solutions.
| ගැටලුව | විය හැකි හේතුව | විසඳුම |
|---|---|---|
| සංදර්ශකය හිස් හෝ ක්රියාත්මක නොවේ. | බල සැපයුමක් නැත. | Check if the controller is properly plugged into a live outlet. Verify the power outlet is functional. |
| Heating/Cooling device (OUT1/OUT2) not turning on/off. | Incorrect temperature settings (ON Temp/OFF Temp). Incorrect time period settings. උපාංගයේ අක්රිය වීම. | Review and adjust ON/OFF temperatures and time periods. Ensure the ON/OFF temperatures are set correctly for heating (ON < OFF) or cooling (ON > OFF). Test the connected device directly in a wall outlet. |
| Timed device (OUT3) not turning on/off. | Incorrect ON/OFF times for OUT3. | Verify the programmed ON/OFF times for Outlet 3. Ensure the current time on the controller is accurate. |
| උෂ්ණත්ව කියවීම් සාවද්යයි. | Probe placement or damage. ක්රමාංකනය අවශ්ය වේ. | Ensure probes are correctly positioned and not directly touching heating elements. Check probes for visible damage. Use the calibration setting (refer to section 5.5) to adjust the temperature reading if necessary (within +/- 12°F). Note that readings are typically accurate within 1-2°F. |
| Settings are lost after a power outage. | This should not occur as the device has memory backup. | If settings are consistently lost, contact customer support. |
8. පිරිවිතර
| විශේෂාංගය | විස්තර |
|---|---|
| මාදිලියේ නම | ටීටීසී -1003 |
| වෙළඳ නාමය | ඩිජිටෙන් |
| උෂ්ණත්ව පාලන පරාසය | 14°F ~ 248°F (-10°C ~ 120°C) |
| වෙළුමtage | 100-240V ඒසී |
| ශ්රේණිගත ධාරාව | 15A උපරිම |
| වට්tage | 2200W |
| සංදර්ශක වර්ගය | පසුතල ආලෝකය සහිත එල්සීඩී |
| පාලන වර්ගය | තල්ලු බොත්තම |
| සම්බන්ධතා තාක්ෂණය | පෙර වයර් |
| අයිතමයේ බර | රාත්තල් 1.03 (දළ වශයෙන් කිලෝග්රෑම් 0.47) |
| පැකේජ මානයන් | අඟල් 6.54 x 6.34 x 2.05 |
9. වගකීම් සහ සහාය
9.1 නිෂ්පාදන වගකීම්
DIGITEN provides a one-year warranty for any quality problems with this product. Please retain your proof of purchase for warranty claims.
9.2 පාරිභෝගික සහාය
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact DIGITEN customer support. You can find contact information and additional resources by visiting the official DIGITEN store: