NJTY T3

NJTY T3 Multimeter Instruction Manual

ආකෘතිය: T3

හැඳින්වීම

This manual provides detailed instructions for the safe and effective use of the NJTY T3 Digital Multimeter. Please read this manual thoroughly before operation and retain it for future reference. The NJTY T3 is a rechargeable, auto-ranging digital multimeter designed for accurate measurements of AC/DC voltage, resistance, and features Non-Contact Voltage (NCV) detection and live wire testing.

NJTY T3 Multimeter with probes and charging cable

Image: The NJTY T3 Digital Multimeter, showing its main unit, red and black test probes, and a USB-C charging cable connected.

ආරක්ෂිත තොරතුරු

Always adhere to safety precautions when using any electrical testing equipment. Failure to do so may result in injury or damage to the device.

පැකේජයේ අන්තර්ගතය

සියලුම අයිතම පැකේජයේ ඇති බව තහවුරු කරගන්න:

සැලසුම

1. මූලික අයකිරීම

The NJTY T3 Multimeter features a built-in rechargeable Lithium Ion battery. Before first use, or if the low battery indicator is displayed, charge the device using the provided Type-C charging cable.

  1. Connect the Type-C end of the charging cable to the multimeter's charging port.
  2. Connect the USB-A end of the charging cable to a standard USB power adapter (not included) or a computer's USB port.
  3. The charging indicator on the multimeter will illuminate during charging and turn off when fully charged.
NJTY T3 Multimeter connected to a laptop via Type-C charging cable

Image: The NJTY T3 Multimeter being charged via its Type-C port, connected to a laptop.

2. පරීක්ෂණ මඟ පෙන්වීම් සම්බන්ධ කිරීම

Insert the red test lead into the "VΩ" input jack and the black test lead into the "COM" input jack. Ensure they are securely seated.

මෙහෙයුම් උපදෙස්

The NJTY T3 Multimeter features an auto-ranging function, simplifying operation by automatically detecting the measurement type and range.

1. බලය සක්‍රිය / අක්‍රිය කරන්න

Press and hold the power button to turn the multimeter on or off. The device will automatically shut off after approximately 15 minutes of inactivity to conserve battery life.

2. Automatic Measurement (Auto-Ranging)

In auto-ranging mode, the multimeter will automatically identify and measure AC voltagඊ, ඩීසී වෙළුමtage, or resistance when the test leads are applied to a circuit. The display will show the measurement type (AC, DC, Ω) and the value.

NJTY T3 Multimeter displaying 'Auto function scan' with icons for various measurement modes

Image: The NJTY T3 Multimeter screen showing "Auto function scan" and icons representing AC/DC voltage, resistance, continuity, NCV, and flashlight functions.

3. AC/DC වෙළුමtagඊ මැනීම

  1. Ensure the multimeter is powered on.
  2. පරීක්ෂණ ලීඩ් පරිපථ ලක්ෂ්‍යවලට සම්බන්ධ කරන්න, එහිදී වෝල්tage needs to be measured. The multimeter will automatically detect AC or DC voltage.
  3. වෙළුම කියවන්නtage අගය තිරයේ දිස්වේ.
NJTY T3 Multimeter performing AC and DC voltagඊ පරීක්ෂණ

Image: Two separate images showing the NJTY T3 Multimeter measuring AC voltage from a power strip and DC voltag9V බැටරියකින්.

4. ප්රතිරෝධය මැනීම

  1. වැදගත්: ප්‍රතිරෝධය මැනීමට පෙර පරිපථය ක්‍රියා විරහිත කර ඇති බවට වග බලා ගන්න.
  2. Connect the test leads across the component or circuit section where resistance is to be measured.
  3. The multimeter will display the resistance value in Ohms (Ω), Kilo-Ohms (KΩ), or Mega-Ohms (MΩ).
NJTY T3 Multimeter performing resistance and continuity tests

Image: Two separate images showing the NJTY T3 Multimeter measuring resistance of a resistor and performing a continuity test on a wire.

5. සම්බන්ධතා නොවන වෙළුමtage (NCV) හඳුනාගැනීම

The NCV function allows for safe detection of live wires without direct contact.

  1. Press the NCV button (if available, or ensure NCV mode is active).
  2. Bring the NCV sensor at the top of the multimeter close to the wire or outlet.
  3. The multimeter will emit an audible beep and the display will indicate the presence of AC voltage, with increasing intensity as it gets closer to the source.
NJTY T3 Multimeter performing NCV detection near an electrical outlet

Image: The NJTY T3 Multimeter detecting non-contact voltage near an electrical wall outlet, with the screen showing "EF" and a signal strength indicator.

6. Live Wire Testing

This function helps identify live wires in an AC circuit.

  1. Insert the red test probe into the socket or touch it to the wire you want to test.
  2. If the multimeter emits an alarm sound and the screen changes to indicate "LIVE", it signifies a live wire.
NJTY T3 Multimeter performing live wire testing on an electrical outlet

Image: The NJTY T3 Multimeter's red probe inserted into an electrical outlet for live wire testing, with the screen displaying "LIVE".

7. අඛණ්ඩ පරීක්ෂණය

  1. වැදගත්: අඛණ්ඩතා පරීක්ෂණයක් සිදු කිරීමට පෙර පරිපථය ක්‍රියා විරහිත කර ඇති බවට වග බලා ගන්න.
  2. Connect the test leads across the component or wire to be tested.
  3. If continuity exists (resistance is low, typically below 50Ω), the multimeter will emit an audible beep.

8 දත්ත රඳවා තබා ගැනීම

Press the "HOLD" button to freeze the current reading on the display. Press it again to release the hold function.

9. Flashlight and Backlight

The multimeter includes a built-in flashlight for illuminating the test area and a backlight for the display, enhancing visibility in low-light conditions. Refer to the device buttons for activation (typically a short press of the power button or a dedicated light button).

NJTY T3 Multimeter with flashlight illuminated

Image: The NJTY T3 Multimeter with its integrated flashlight active, illuminating a dark electrical panel.

නඩත්තු කිරීම

1 පිරිසිදු කිරීම

Wipe the multimeter's case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is off and disconnected from any power source before cleaning.

2. බැටරි රැකවරණය

The built-in Lithium Ion battery should be charged regularly, especially if the device is not used for extended periods. The automatic shut-off feature helps prolong battery life. A low battery indicator will appear on the display when charging is required.

NJTY T3 Multimeter displaying a low battery warning

Image: The NJTY T3 Multimeter screen showing a low battery warning icon, indicating the need for recharging.

3. ගබඩා කිරීම

Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures. Disconnect test leads when storing.

දෝෂගවේෂණය

ගැටලුවවිය හැකි හේතුවවිසඳුම
කිසිදු සංදර්ශකයක් හෝ උපාංගයක් ක්‍රියාත්මක නොවේ.බැටරිය අඩුයි හෝ උපාංගය ක්‍රියා විරහිතයි.Charge the battery using the Type-C cable. Press and hold the power button to turn on.
වැරදි කියවීම්.Poor test lead connection, incorrect measurement technique, or exceeding input limits.Ensure test leads are firmly connected. Review operating instructions for correct measurement procedures. Do not exceed specified input ranges.
Multimeter automatically shuts off.Automatic power-off feature activated due to inactivity.This is normal behavior to conserve battery. Press the power button to turn it back on.
NCV detection not working or inconsistent.Distance to voltage source too far, or interference.Bring the NCV sensor closer to the suspected live wire. Ensure no other strong electromagnetic fields are present.

පිරිවිතර

විශේෂාංගයවිස්තර
ප්රදර්ශනය කරන්න4000 Counts, 3.19-inch Color LCD
ඩීසී වෙළුමtagඊ පරාසය0.8V - 600V (Accuracy: ±(0.8%+5))
ඒසී වෙළුමtagඊ පරාසය1V - 600V (Accuracy: ±(1.0%+5))
ප්රතිරෝධක පරාසය0 - 40MΩ (Accuracy: ±(1.0%+10))
Minimum Resolution (DCV/ACV)0.001V
Minimum Resolution (Resistance)
බලශක්ති ප්රභවයනැවත ආරෝපණය කළ හැකි ලිතියම් අයන බැටරි (ඇතුළත්)
ආරෝපණ වරායවර්ගය-C
ස්වයංක්‍රීයව වසා දැමීමආසන්න වශයෙන් මිනිත්තු 15 ක අක්‍රියතාව
ෆ්ලෑෂ් ලයිට්Yes (1 minute auto shut-off)
පසුතල ආලෝකයඔව්
බසර්Yes (for continuity, internal resistance less than 50Ω)
NCV හඳුනා ගැනීමඔව්
ඇත්ත RMSYes (45Hz-2KHz)
අඩු බැටරි දර්ශකයඔව්
සජීවී වයර් හඳුනාගැනීමඔව්
නිෂ්පාදන මානයන්අඟල් 5.51 x 1.18 x 0.79
අයිතමයේ බරග්රෑම් 150 (අවුන්ස 5.29)
NJTY T3 Multimeter NCV detection and detailed specifications table

Image: The NJTY T3 Multimeter demonstrating NCV detection alongside a table detailing its technical specifications.

වගකීම් සහ සහාය

වගකීම් තොරතුරු

For specific warranty terms and conditions, please refer to the warranty card included with your product or contact the seller directly. Warranty coverage typically addresses manufacturing defects under normal use.

පාරිභෝගික සහාය

If you encounter any issues or have questions regarding the NJTY T3 Multimeter, please contact your retailer or the manufacturer's customer support channel. Refer to the "after-sales channel" information provided in your product packaging for contact details.

අදාළ ලියකියවිලි - T3

පෙරview NJTY T21L LCR Meter: Auto-ranging Digital Multimeter with TRUE RMS - User Manual
User manual for the NJTY T21L LCR Meter, an auto-ranging digital multimeter with TRUE RMS. Covers features, safety, technical specifications, and operation for accurate electrical measurements.
පෙරview NJTY T21L LCR Meter: Auto-ranging Digital Multimeter with TRUE RMS - User Manual
Comprehensive user manual for the NJTY T21L LCR Meter, an auto-ranging digital multimeter with TRUE RMS. Covers specifications, safety, operation, and measurement functions for voltage, current, resistance, capacitance, inductance, frequency, and temperature.
පෙරview NJTY පොයින්ටර් බහුමාපක පරිශීලක මාර්ගෝපදේශය: විශේෂාංග, පිරිවිතර සහ උපදෙස්
NJTY පොයින්ටර් බහුමාපකය සඳහා වන පුළුල් පරිශීලක මාර්ගෝපදේශය, එහි පෙනුම, පිරිවිතර, මිනුම් කාර්යයන් විස්තර කරයි (DC/AC වෙළුමtage, ධාරාව, ​​ප්‍රතිරෝධය, ධාරිතාව, ආදිය), සහ වැදගත් ආරක්ෂක මතක් කිරීම්.
පෙරview NJTY S18D Digital Multimeter User Manual
User manual for the NJTY S18D Digital Multimeter, detailing safety instructions, panel indications, operational guidelines, and technical specifications for accurate electrical measurements. Features include IEC-61010 compliance, backlit LCD, True RMS, and auto-ranging.
පෙරview NJTY 88 Series Analog Multimeter: User Manual & Technical Guide
Comprehensive user manual for the NJTY 88 series analog multimeters, covering features, specifications, safety precautions, and measurement instructions for DC/AC voltage and current, resistance, capacitance, frequency, and more.
පෙරview NJTY T60 Series Insulation Resistance Tester Instruction Manual
Detailed instruction manual for NJTY T6005, T6010, and T6015 analog insulation resistance testers, covering features, operation, safety, technical specifications, and package contents.