TONGOU TOSAR-RD4A-2-40-003

TONGOU TOSAR-RD4A-2-40-003 Type A 1P+N 230V 40A 30mA Auto-Reclosing Residual Current Device User Manual

1. නිෂ්පාදන අවසන්view

The TONGOU TOSAR-RD4A-2-40-003 is a Type A 1P+N 230V 40A 30mA auto-reclosing residual current device (RCD). It is engineered for stable operation in 230V AC 50Hz/60Hz electrical networks, providing enhanced electrical safety for a variety of applications including residential homes, commercial buildings, and smart home systems. This device incorporates an advanced triple automatic reclosing function with staggered delays, designed to ensure continuous power supply while maintaining critical safety standards.

TONGOU TOSAR-RD4A-2-40-003 Auto-Reclosing Residual Current Device

රූපය 1: ඉදිරිපස view of the TONGOU TOSAR-RD4A-2-40-003 auto-reclosing residual current device, showcasing its compact design and clear labeling.

2 ප්රධාන ලක්ෂණ

TONGOU RCCB Type A with reclosing auto, 30mA/40A/Inc:6KA

Figure 2: An image highlighting the key specifications of the TONGOU RCD: RCCB Type A, with reclosing auto, 30mA, 40 Amp, and an Inc (short-circuit current) of 6KA. Below are illustrative images of typical applications.

TONGOU TOSAR-RD4A-2-40-003 Dry Contact Control

රූපය 3: සමීප රූපයක් view of the TONGOU RCD showing the dry contact control terminals, labeled 1 to 6, indicating external control capabilities.

TONGOU TOSAR-RD4A-2-40-003 Product Details

Figure 4: Detailed product features including ergonomic design, fire-retardant casing, convenient design for distribution boxes, and quick installation on DIN rails.

TONGOU TOSAR-RD4A-2-40-003 Electrical and Mechanical Life

Figure 5: A graph comparing the mechanical and electrical life cycles of TONGOU products against national standards, along with key electrical specifications and certifications.

TONGOU TOSAR-RD4A-2-40-003 Operating Temperature Range

Figure 6: An illustration of the wide operating temperature range of the TONGOU RCD, from -40°C to +85°C, ensuring reliability in diverse environmental conditions.

3. පිහිටුවීම සහ ස්ථාපනය

WARNING: Installation must be performed by a qualified electrician in accordance with local electrical codes and regulations. Ensure power is disconnected before installation to prevent electric shock or damage to the device.

3.1 සවි කිරීම

The TONGOU TOSAR-RD4A-2-40-003 is designed for DIN rail mounting. Securely attach the device to a standard 35mm DIN rail within your electrical panel. Ensure it is firmly clipped into place.

3.2 රැහැන්

Connect the device according to the provided wiring diagram. Ensure correct connection of Line (L) and Neutral (N) conductors. The device is 1P+N, meaning it provides protection for one phase and the neutral conductor.

TONGOU TOSAR-RD4A-2-40-003 Wiring Diagram

Figure 7: A detailed wiring diagram illustrating the connection of the TONGOU RCD within an electrical circuit, including input/output and dry contact control wiring.

TONGOU TOSAR-RD4A-2-40-003 Technical Circuit Diagram

Figure 8: A technical circuit diagram showing internal components and wiring paths of the TONGOU RCD, with important safety warnings.

TONGOU TOSAR-RD4A-2-40-003 Installation Steps

Figure 9: A visual guide outlining four numbered steps for the correct installation of the TONGOU RCD, emphasizing proper mounting and connection procedures.

3.3 Dry Contact Connections

The automatic recloser features 6 contacts for external control. Refer to the wiring diagram (Figure 7) for specific connections and functions:

These contacts are rated for a nominal voltagAC 100-240V හි ඊ.

4. මෙහෙයුම් උපදෙස්

4.1 බල ගැන්වීම සක්‍රිය / අක්‍රිය කිරීම

To power on the device, ensure the main switch or lever is in the 'ON' position. To power off, move the switch or lever to the 'OFF' position. Always ensure the load is disconnected before powering off for safety.

4.2 Automatic Reclosing Function

In automatic mode, if an electrical fault causes the device to trip, it will initiate a sequence of up to three reclosing attempts. These attempts occur with specific staggered delays:

If a reclosure is successful and the device operates stably for more than 15 minutes, the system determines that the fault has been cleared. The reclosing counter will then reset, and the device will return to its initial operational state.

If three consecutive reclosing attempts fail (either the device is unable to reclose or it trips again immediately after reclosing), the device will interpret this as a permanent fault. In this scenario, the automatic reclosing function will be locked out, and manual intervention will be required to reset the device after the fault has been addressed.

4.3 Mode Selection (Manual/Auto)

The device allows users to switch between automatic and manual recloser modes. Use the designated switch or button on the device to select the desired mode. In manual mode, the automatic reclosing function is disabled, providing direct control over the circuit breaker's state.

4.4 Manual Lockout

A manual lockout function is available to intentionally prevent automatic reclosing. This feature is particularly useful during maintenance procedures or when a persistent fault requires thorough investigation, ensuring the circuit remains open until manually reset. Consult the device's physical controls for engaging this function.

4.5 LED සංදර්ශකය

The integrated LED display provides clear visual feedback on the device's operational status. Observe the display for indicators such as countdowns during reclosing attempts, fault codes, or the current status (e.g., 'ON' or 'OFF').

TONGOU TOSAR-RD4A-2-40-003 Visual Window Status

Figure 10: An image showing the visual window of the TONGOU RCD. A white indicator signifies 'CLOSED' (in use), while a red indicator signifies 'TRIPPED' (fault detected).

5. නඩත්තු කිරීම

The TONGOU TOSAR-RD4A-2-40-003 is engineered for reliable operation with minimal maintenance requirements. However, periodic checks are highly recommended to ensure optimal performance and continued safety.

Always disconnect power to the circuit before performing any maintenance, inspection, or cleaning to prevent electric shock.

6. දෝශ නිරාකරණය

If the TONGOU TOSAR-RD4A-2-40-003 trips frequently or fails to reclose as expected, consider the following troubleshooting steps:

Do not attempt to repair the device yourself. For any issues beyond basic troubleshooting, or if you are unsure about the cause of a fault, contact a qualified electrician for professional assistance.

7. තාක්ෂණික පිරිවිතර

විශේෂාංගයපිරිවිතර
ආදර්ශ අංකයTOSAR-RD4A-2-40-003
වෙළඳ නාමයTONGOU
ශ්‍රේණිගත ධාරාව40 Amperes
Rated Residual Current30 mA
ටයිප් කරන්නType A (AC sinusoidal and pulsating DC residual currents)
ධ්රැව සංඛ්යාව1P+N (1 Phase + Neutral)
ශ්‍රේණිගත කළ වෙළුමtage230V AC
සංඛ්යාතය50Hz/60Hz
Short-Circuit Current (Inc)6KA
Reclosing Attempts3 වාරයක්
Reclosing Delaysතත් 10/60/300 තත්
සවිකිරීමේ වර්ගයඩීඑන් රේල් කන්ද
මෙහෙයුම් උෂ්ණත්වය-40 ° C සිට +85 ° C
මානයන් (ආසන්න වශයෙන්)9.5 x 5.4 x 5 සෙ.මී
නිෂ්පාදන බර (ආසන්න වශයෙන්)260 ග්රෑම්
සහතිකCB, CE, CCC, TUV
ඇතුළත් සංරචක1 smart circuit breaker and user manual
නිෂ්පාදකයාChangyou Technology (Zhejiang) Co., Ltd.
පළමු ලබා ගත හැකි දිනය24 මැයි 2025
TONGOU TOSAR-RD4A-2-40-003 Product Dimensions

Figure 11: A diagram illustrating the physical dimensions of the TONGOU RCD for both 1P+N and 3P+N variants, showing height, width, and depth measurements.

8. වගකීම් සහ සහාය

For detailed warranty information, technical support, or service inquiries regarding your TONGOU TOSAR-RD4A-2-40-003 device, please contact the seller or manufacturer directly. It is recommended to retain your purchase receipt as proof of purchase for any warranty claims.

නිෂ්පාදකයා: Changyou Technology (Zhejiang) Co., Ltd.

අදාළ ලියකියවිලි - TOSAR-RD4A-2-40-003

පෙරview TONGOU TOSAR-1DB00-AC1 40A 30mA Type A 1P+N 230V Residual Current Device User Manual
Comprehensive user manual for the TONGOU TOSAR-1DB00-AC1 residual current device (RCD). Provides detailed information on features, specifications, installation, operation, and safety precautions for residential and small commercial applications.
පෙරview TONGOU TOSAR-1 Manual Instruction and Technical Specifications
User manual and technical specifications for the TONGOU TOSAR-1 automatic recloser, detailing its features, dimensions, wiring diagrams, and electrical characteristics for circuit protection.
පෙරview Tongou Circuit Breakers: Installation Guide & EU Compliance
Official assembly instructions and EU Declaration of Conformity for Tongou circuit breakers (TORD4B-63, TOMD6-63(DC), TOND6-40, etc.). Details on installation, specifications, and safety for qualified electricians.
පෙරview TOSAR1 Automatic Reclosing Device Manual Instruction
This manual provides detailed instructions for the TOSAR1 Automatic Reclosing Device, covering installation, operation, and technical specifications. It is designed for professionals in the electrical field.
පෙරview Tongou TOQCB1-TJ-100 WiFi මිනුම් පරිපථ කඩනය: මෙහෙයුම් අත්පොත සහ විශේෂාංග
Tongou TOQCB1-TJ-100 WiFi මිනුම් පරිපථ කඩනය සඳහා සවිස්තරාත්මක මෙහෙයුම් අත්පොත. ප්‍රධාන කාර්යයන්, පරාමිති සැකසුම්, සජීවීව ආවරණය කරයි. view, LED දර්ශක, වින්‍යාස කිරීමේ පියවර සහ Smart Life APP සඳහා දුරස්ථ ආරක්ෂණ මාදිලිය.
පෙරview Tongou TOQCB2 Smart Metering Circuit Breaker User Manual & Specifications
Comprehensive user manual and technical specifications for the Tongou TOQCB2 Smart Metering Circuit Breaker, covering installation, functions, features, and safety guidelines.