1. වැදගත් ආරක්ෂක තොරතුරු
Read all instructions carefully before using this device. Failure to follow these instructions may result in product malfunction, property damage, or personal injury. Keep this manual for future reference.
- This device detects carbon monoxide (CO) and combustible gases (natural gas, propane, methane). It is not designed to detect smoke or other gases.
- Do not paint the device. Paint can clog the vents and interfere with sensor operation.
- උපාංගයේ වාතාශ්රය විවරයන් අවහිර නොකරන්න.
- Test the alarm regularly as described in the "Operating Instructions" section.
- අනතුරු ඇඟවීමක් ඇති වුවහොත්, වහාම පරිශ්රයෙන් ඉවත් වී හදිසි සේවා අමතන්න.
- The device requires a standard AC power outlet to operate. Ensure the outlet is functioning correctly.
2. නිෂ්පාදන අවසන්view
The MOES 4-in-1 Gas & Carbon Monoxide Detector is a plug-in device designed to monitor your environment for dangerous levels of carbon monoxide (CO) and combustible gases. It also provides real-time temperature and humidity readings. This device features a clear display and an audible alarm system to alert you to potential hazards.
රූපය: අවසන්view of the MOES 4-in-1 Gas & Carbon Monoxide Detector highlighting its multiple functions.
ප්රධාන ලක්ෂණ:
- 4-එස්tage Gas & CO Alerts: Provides precise risk awareness with Green (Safe), Yellow (Caution), Orange (Warning), and Red (Danger) alert levels based on CO and gas concentrations.
- Dynamic Alarm System: Features an 85dB alarm that increases in sound and frequency as hazard levels rise, complemented by bright LED indicators.
- ප්ලග් ඇන්ඩ් ප්ලේ ස්ථාපනය: No wiring or complex setup required; simply plug into a standard electrical outlet.
- Built-In Temperature & Humidity Monitoring: Continuously displays indoor temperature (14℉–122℉) and humidity (0–95% RH).
- Dual Sensor Protection: Combines carbon monoxide and flammable gas (LPG/Natural Gas) sensors for comprehensive monitoring.
- 2-inch HD Color Screen Display: Clearly visible display for all data.
3. පිහිටුවීම සහ ස්ථාපනය
The MOES 4-in-1 Detector is designed for easy, hassle-free installation.
- උපාංගය ඉවත් කරන්න: අනාවරකය එහි ඇසුරුම්වලින් ප්රවේශමෙන් ඉවත් කරන්න.
- ස්ථානයක් තෝරන්න:
- Install in areas where CO or gas leaks are possible, such as kitchens, boiler rooms, near gas appliances, or fireplaces.
- For CO detection, place the detector at a height where it can effectively detect CO, typically at eye level or higher, but not directly above heat sources.
- For gas detection, if detecting natural gas (lighter than air), install near the ceiling. If detecting propane (heavier than air), install closer to the floor. For general protection, a mid-wall position is often suitable.
- Avoid placing near windows, doors, or ventilation fans where drafts might interfere with readings.
- Avoid placing in direct sunlight or areas with extreme temperature fluctuations.
- ප්ලග් ඉන්: Simply plug the device into a standard 120V AC electrical outlet. The device will power on automatically.
- Initial Warm-up: The device may undergo a brief warm-up period upon first power-up. During this time, the display may show a countdown or initialization sequence.
Image: The MOES detector plugged into a wall outlet, demonstrating its plug-and-play design.
Adjusting the Plug (if applicable):
The device features a disassembling button to adjust the plug orientation for different outlets.
- Press the disassembling button located on the side of the device.
- Twist the plug to the right or left to change its orientation.
- Release the button to lock the plug in the desired position.
Image: Detailed diagram of the detector, showing the plug adjustment mechanism and various display indicators.
4. මෙහෙයුම් උපදෙස්
ප්රදර්ශනය තොරතුරු:
The 2-inch HD color screen displays real-time information:
- CO Unit: PPM (මිලියනයකට කොටස්)
- CO Value: Current Carbon Monoxide concentration.
- GAS Sensitivity: Indication of gas detection level (S1, S2, etc.).
- GAS Level: Current combustible gas concentration level.
- Temp Value: Real-time ambient temperature (in Celsius or Fahrenheit).
- Hum Value: Real-time ambient humidity (in % RH).
- ඇඟවීම් නිරූපකය: Visual indicator for alarm status.
- ශබ්ද නිරූපකය: Indicates alarm sound status.
- CO Indicator: Visual bar for CO levels.
- තිර දීප්තියේ යතුරු: Controls screen illumination.
Image: The clear 2-inch HD color screen display of the MOES detector, showing CO, Gas, Temperature, and Humidity readings.
බොත්තම් කාර්යයන්:
The device features a central button with multiple functions based on press duration.
- Short Press (U button): Initiates a self-test of the alarm system.
- Long Press (U button): Toggles the temperature unit between Celsius (℃) and Fahrenheit (℉).
- Short Press (Bell icon): Toggles the alarm sound on or off (mute/unmute).
- Long Press (Bell icon): Flips the screen display 180 degrees for flexible viewදිශානතිය.
- Screen Brightness Keys (Light icon):
- පළමු ගියරය: 100% Brightness.
- දෙවන ගියර්: 50% Brightness.
- තුන්වන ගියර්: 0% Brightness (Screen is off, breathing light is turned off).
Image: Explanation of button functions, including short and long presses for various settings.
Image: Demonstration of the screen inversion feature, allowing the display to be flipped 180 degrees.
Alert Levels and Alarm Behavior:
The detector provides four distinct alert levels, each with specific CO and gas concentration thresholds, visual indicators, and alarm responses.
| මට්ටම | CO සාන්ද්රණය | ගෑස් සාන්ද්රණය | දෘශ්ය දර්ශකය | ඇසෙන අනතුරු ඇඟවීම |
|---|---|---|---|---|
| Green (Safe) | < 50ppm | < 5% LEL (Lower Explosive Limit) | හරිත දර්ශක ආලෝකය | ඇසෙන අනතුරු ඇඟවීමක් නැත |
| Yellow (Caution) | 51-100ppm | 5-8% LEL | Yellow indicator light flashes | Slowly audible alarm |
| Orange (Warning) | 101-150ppm | 8-15% LEL | තැඹිලි දර්ශක ආලෝකය දැල්වෙයි | Fast audible alarm |
| Red (Danger) | 150-999ppm | >15% LEL | රතු දර්ශක ආලෝකය දැල්වෙයි | Very fast audible alarm |
Image: Visual representation of the four alert stages for CO and gas detection.
Image: Flowchart detailing the four levels of visual and audible alarms.
5. භාවිත අවස්ථා
The MOES 4-in-1 Detector is suitable for various indoor environments where carbon monoxide or combustible gases may be present.
- Fireplace Areas: To detect CO from burning wood or other fuels.
- මුළුතැන්ගෙයි: To detect natural gas or propane leaks from stoves and ovens.
- ගරාජ: To monitor for CO from vehicle exhaust.
- Boiler Rooms/Utility Rooms: Near water heaters, furnaces, or other gas-powered appliances.
- RV/Camping: For portable protection in recreational vehicles (ensure proper power supply).
- Smoking Areas: While the device is not a smoke detector, it can detect some byproducts of combustion.
Image: The detector monitoring for gas near a stove and for CO near a fireplace.
රූපය: උදාamples of suitable locations for the detector, including kitchens, fireplaces, and garages.
Image: A broader view of potential installation sites for comprehensive safety.
6. නඩත්තු කිරීම
Regular maintenance ensures the optimal performance and longevity of your MOES detector.
- මාසික පරීක්ෂණය: Perform a self-test at least once a month by short-pressing the 'U' button. The alarm should sound, and indicators should light up.
- පිරිසිදු කිරීම: Gently wipe the exterior of the detector with a soft, damp cloth. Do not use cleaning agents, solvents, or abrasive materials. Ensure the ventilation openings are free from dust and debris.
- බාධා වළක්වා ගන්න: Ensure that nothing is blocking the sensor openings or the alarm speaker.
- බල සැපයුම: Ensure the device remains continuously plugged into a functioning power outlet.
7. දෝශ නිරාකරණය
If you encounter issues with your MOES detector, refer to the following common troubleshooting steps:
- Alarm Sounds Without Apparent Hazard:
- ව්යාජ අනතුරු ඇඟවීම: Ensure there are no temporary sources of CO (e.g., car exhaust from an attached garage, fireplace smoke) or gas (e.g., pilot light issues, strong cleaning fumes) that could trigger the sensor.
- සංවේදක දූෂණය: Strong chemicals, paint fumes, or excessive dust can sometimes trigger the alarm. Ventilate the area.
- නැවත ස්ථානගත කරන්න: If false alarms persist, try relocating the detector to a different area.
- සංදර්ශකයක්/උපාංගයක් ක්රියාත්මක නොවේ:
- බල සැපයුම පරීක්ෂා කරන්න: Ensure the outlet is live and functioning. Test with another appliance.
- Re-plug Device: Unplug and re-plug the detector firmly into the outlet.
- තිරයේ දීප්තිය: Check if the screen brightness is set to 0% (off). Adjust using the brightness keys.
- සාවද්ය උෂ්ණත්ව/ආර්ද්රතා කියවීම්:
- පාරිසරික සාධක: Ensure the detector is not in direct sunlight, near heat sources, or in an area with high airflow that could affect readings.
- ක්රමාංකනය: While the device is factory calibrated, significant discrepancies might indicate a sensor issue.
- Self-Test Fails: If the alarm does not sound during a self-test, the device may be faulty. Do not rely on a faulty detector; replace it immediately.
If issues persist after attempting these steps, contact MOES customer support for further assistance.
8. පිරිවිතර
| විශේෂාංගය | විස්තර |
|---|---|
| ආදර්ශ අංකය | NA503F |
| හඳුනාගැනීමේ වායු | Carbon Monoxide (CO), Combustible Gases (Natural Gas, Propane, Methane) |
| බලශක්ති ප්රභවය | AC (ප්ලගිනය) |
| අනතුරු ඇඟවීමේ ශබ්දය | 85dB |
| උෂ්ණත්ව පරාසය | 14℉–122℉ (-10℃–50℃) |
| ආර්ද්රතා පරාසය | 0-95% RH (ඝනීභවනය නොවන) |
| අයිතමයේ බර | අවුන්ස 3.42 (ග්රෑම් 97) |
| පැකේජ මානයන් | අඟල් 4.49 x 4.25 x 2.24 |
| නිෂ්පාදකයා | WENZHOU NOVA NEW ENERGY CO.,LTD |
9. වගකීම් සහ සහාය
For warranty information and customer support, please refer to the documentation included with your purchase or visit the official MOES webවෙබ් අඩවිය. මිලදී ගැනීම පිළිබඳ සාක්ෂියක් ලෙස ඔබේ මිලදී ගැනීමේ රිසිට්පත තබා ගන්න.
MOES Customer Support: Amazon හි MOES වෙළඳසැලට පිවිසෙන්න