OWON ADS824A

OWON ADS824A 200MHz 4-Channel Digital Oscilloscope User Manual

1. හැඳින්වීම

This manual provides instructions for the safe and effective operation of the OWON ADS824A Digital Oscilloscope. The ADS824A is a 200MHz, 4-channel, 12-bit digital oscilloscope designed for high-precision testing. It features a 1.25GSa/s real-time sampling rate and a 50M storage depth, making it suitable for signal integrity verification, circuit fault identification, digital circuit design, debugging, and automotive electronics testing. This device integrates an oscilloscope, frequency counter, voltmeter, and FFT spectrum analyzer into a single unit.

2. නිෂ්පාදන අවසන්view

2.1 ප්රධාන ලක්ෂණ

2.2 පෙට්ටියේ ඇති දේ

The OWON ADS824A package typically includes:

2.3 භෞතික කාලයview

OWON ADS824A Front View

රූපය 2.3.1: ඉදිරිපස view of the OWON ADS824A Digital Oscilloscope, showing the display and control panel.

OWON ADS824A Front Panel with Key Specifications

Figure 2.3.2: Front panel highlighting key specifications such as 4 channels, 1.25GSa/s, 200MHz bandwidth, and 700,000 wfms/s refresh rate.

OWON ADS824A Control Knobs

රූපය 2.3.3: සමීප රූපය view of the control knobs for horizontal and vertical adjustments.

OWON ADS824A Rear Panel Interfaces

Figure 2.3.4: Rear panel showing the LAN, USB Device, HDMI, and USB-C Power interfaces.

OWON ADS824A Top and Rear View මානයන් සමඟ

Figure 2.3.5: Top and rear view illustrating the overall dimensions and port layout.

3. පිහිටුවීම

3.1 බල සම්බන්ධතාවය

  1. Connect the provided power adapter to the USB-C Power interface on the rear panel of the oscilloscope.
  2. බල ඇඩැප්ටරය සුදුසු AC බල අලෙවිසැලකට සම්බන්ධ කරන්න.
  3. උපාංගය සක්‍රිය කිරීමට ඉදිරිපස පුවරුවේ ඇති බල බොත්තම ඔබන්න.

3.2 පරීක්ෂණ සම්බන්ධතාවය

  1. Connect the BNC connector of the oscilloscope probe to one of the four input channels (CH1-CH4) on the front panel.
  2. Ensure the probe's ground clip is securely connected to the ground reference of the circuit under test.
  3. Attach the probe tip to the test point on the circuit.

4. මෙහෙයුම් උපදෙස්

4.1 මූලික මෙහෙයුම

The ADS824A features a 7-inch multi-touch display for intuitive control.

OWON ADS824A 7-inch Multi-touch Screen

Figure 4.1.1: The 7-inch multi-touch TFT-LCD display allows for direct interaction with the waveform and menu settings.

4.2 Waveform Display and Control

OWON ADS824A Waveform Capture Rate Display

Figure 4.2.1: Illustration of the waveform capture rate, showing the ability to display complex signals effectively.

4.3 මිනුම් කාර්යයන්

The ADS824A offers extensive measurement capabilities:

OWON ADS824A Auto Measurements and Glossary

Figure 4.3.1: Display showing the interface for 43 auto measurements and the technical terms glossary.

OWON ADS824A Parametric Statistics and Cursor Gating

Figure 4.3.2: Screen views demonstrating parametric statistics and cursor gating with visual indicators.

4.4 අවුලුවාලීම

The oscilloscope supports various triggering options to capture specific events:

OWON ADS824A Advanced Triggering and Hardware Decoding

Figure 4.4.1: Interface showing advanced triggering options and hardware decoding capabilities.

4.5 උසස් කාර්යයන්

OWON ADS824A Multi-Function Digital Phosphor Oscilloscope with FFT and Grayscale Display

Figure 4.5.1: Display illustrating the FFT spectrum analysis and 256-level grayscale display features.

OWON ADS824A Storage Depth, Voltmeter, and Frequency Counter

Figure 4.5.2: Screen views demonstrating 50Mpts storage depth settings, 4-digit voltmeter, and 6-digit frequency counter.

OWON ADS824A 12-bit High-Resolution Oscilloscope Comparison

Figure 4.5.3: Comparison illustrating the enhanced detail provided by the 12-bit high-resolution display compared to a standard oscilloscope.

4.6 බාහිර උපාංග සම්බන්ධතාවය

The ADS824A supports various external devices:

5. නඩත්තු කිරීම

5.1 පිරිසිදු කිරීම

උපාංගයේ ක්‍රියාකාරිත්වය සහ පෙනුම පවත්වා ගැනීම සඳහා:

5.2 ගබඩා කිරීම

When not in use, store the oscilloscope in a clean, dry environment away from direct sunlight and extreme temperatures.

5.3 බැටරි සත්කාර

The ADS824A includes a built-in lithium battery for portability. Proper battery care ensures longevity:

OWON ADS824A Built-in Lithium Battery Benefits

Figure 5.3.1: Information regarding the built-in lithium battery, emphasizing portability and ground loop avoidance.

6. දෝශ නිරාකරණය

This section addresses common issues you might encounter with the OWON ADS824A oscilloscope.

ගැටලුවවිය හැකි හේතුවවිසඳුම
බලය නැතPower adapter not connected or faulty; battery discharged.Check power connections. Ensure adapter is working. Charge the battery.
තරංග ආකාරයක් ප්‍රදර්ශනය කර නැතProbe not connected; signal too small/large; incorrect trigger settings.Verify probe connection. Adjust vertical scale (V/div). Press 'Autoset'. Check trigger level and mode.
අස්ථායී තරංග ආකාරයIncorrect trigger level or mode; noisy signal.Adjust trigger level. Change trigger mode. Use averaging acquisition mode.
තිරය ​​ප්‍රතිචාර නොදක්වයිතාවකාලික මෘදුකාංග දෝෂයක්.Restart the device. If issue persists, contact support.

7. පිරිවිතර

Detailed technical specifications for the OWON ADS824A Digital Oscilloscope.

OWON ADS824A Oscilloscope Specifications Table

Figure 7.1.1: Table detailing key oscilloscope specifications including bandwidth, sampling rate, and vertical resolution.

පරාමිතියවටිනාකම
කලාප පළල200 MHz
නාලිකා4
Sampලිං අනුපාතය1.25 GSa/s (Real-time)
Max. Waveform Capture Rate700,000 wfms/s
Max Memory Depth50 Mpts
සිරස් විභේදනයබිටු 12ක්
සිරස් සංවේදීතා පරාසය500 uV/div - 10 V/div
ආදාන සම්බාධනය1 MΩ±2%, parallel with 20 pF±5 pF
කාල පාදක පරාසය1 ns/div - 1000 s/div
කාල පාදක නිරවද්‍යතාවය±(0.01% + 0.1tdv)
Bus DecodingRS232/UART, I2C, SPI, CAN, LIN
ආදාන සම්බන්ධ කිරීමDC, AC, Ground
නිෂ්පාදන මානයන්අඟල් 10.25 x 3.07 x 6.3
අයිතමයේ බරරාත්තල් 3.3 කි

8. වගකීම් සහ සහාය

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official OWON website. Contact details for customer service are typically available on the manufacturer's support page.

අදාළ ලියකියවිලි - ADS824A

පෙරview OWON TAO3000 Series Handheld Oscilloscopes User Manual
User manual for the OWON TAO3000 Four-Channel Series Handheld Oscilloscopes, detailing operation, features, technical specifications, and troubleshooting.
පෙරview OWON HDS200 ශ්‍රේණියේ අතේ ගෙන යා හැකි ඔසිලෝස්කෝප් පරිශීලක අත්පොත - ක්‍රියාකාරිත්වය සහ පිරිවිතර
මෙම සවිස්තරාත්මක පරිශීලක අත්පොත, HDS272(S) සහ HDS242(S) මාදිලි ඇතුළුව, OWON HDS200 ද්විත්ව නාලිකා ශ්‍රේණියේ අතේ ගෙන යා හැකි දෝලන දර්ශන ක්‍රියාත්මක කිරීම සඳහා සවිස්තරාත්මක උපදෙස් සපයයි. එය තාක්ෂණික පිරිවිතර සහ නඩත්තු මාර්ගෝපදේශ සමඟ ආරක්ෂිත තොරතුරු, සාමාන්‍ය පරීක්ෂාව, දෝලන දර්ශනය, බහුමාපකය සහ විකල්ප තරංග ආකෘති උත්පාදක කාර්යයන් ආවරණය කරයි.
පෙරview OWON HDS200 Series 2-Channel Portable Oscilloscope Quick Start Guide
This quick start guide provides essential information for operating the OWON HDS200 Series 2-channel portable oscilloscopes, including models HDS272, HDS242, HDS2102, and HDS2202. It covers safety precautions, general inspection, oscilloscope and multimeter usage, signal generator functions, software connectivity, troubleshooting, and maintenance.
පෙරview OWON FDS Dual-Channel Series Quick Guide: Oscilloscope, Function Generator, Power Supply, Multimeter
This quick guide provides essential information for operating the OWON FDS Dual-Channel Series, a versatile instrument featuring an oscilloscope, arbitrary waveform/function generator, power supply, and multimeter. Learn about safety, basic functions, and operational tips from Fujian LILLIPUT Optoelectronics Technology Co., Ltd.
පෙරview OWON HDS20 ශ්‍රේණියේ අතේ ගෙන යා හැකි ඔසිලෝස්කෝප් ඉක්මන් මාර්ගෝපදේශය
HDS25(S) වැනි මාදිලි ඇතුළුව, OWON HDS20 ද්විත්ව නාලිකා මාලාවේ අතේ ගෙන යා හැකි දෝලන දර්ශන සඳහා ඉක්මන් ආරම්භක මාර්ගෝපදේශය. එහි විශේෂාංග, ක්‍රියාකාරිත්වය, ආරක්ෂාව සහ දෝශ නිරාකරණය ගැන ඉගෙන ගන්න.
පෙරview OWON HDS200 ශ්‍රේණියේ අතේ ගෙන යා හැකි ඔසිලෝස්කෝප් ඉක්මන් මාර්ගෝපදේශය
This quick guide provides essential information for operating the OWON HDS200 Series Handheld Oscilloscope. It covers product certification, safety precautions, detailed instructions for using the oscilloscope and multimeter functions, waveform generator operation, troubleshooting common issues, and maintenance procedures.