FNIRSI LC1020E

FNIRSI LC1020E 100kHz LCR Meter and SMD Tester User Manual

මාදිලිය: LC1020E

1. ඉවරයිview

The FNIRSI LC1020E is a handheld LCR meter designed for precise measurement of inductance, capacitance, and resistance. It features a dual-parameter display, allowing simultaneous viewing of main and secondary parameters such as X, D, Q, θ, and ESR. With multiple test frequencies and voltage levels, it provides accurate readings for various electronic components. The device also includes a smart sorting function for efficient component screening.

2 ආරක්ෂිත තොරතුරු

උපාංගය ක්‍රියාත්මක කිරීමට පෙර කරුණාකර සියලු ආරක්ෂක උපදෙස් කියවා තේරුම් ගන්න. මෙම උපදෙස් අනුගමනය කිරීමට අපොහොසත් වීමෙන් විදුලි කම්පනය, ගින්නක් හෝ උපාංගයට හානි සිදුවිය හැකිය.

3. පිහිටුවීම

3.1 උපාංගය බල ගැන්වීම

The LC1020E is typically powered by an internal rechargeable battery or an external power source. Ensure the device is sufficiently charged before use. Connect the appropriate power adapter if external power is required.

3.2 පරීක්ෂණ මඟ පෙන්වීම් සම්බන්ධ කිරීම

Connect the provided test leads to the input terminals on the LCR meter. Ensure a secure connection to prevent inaccurate readings or damage.

FNIRSI LC1020E LCR Meter with test leads connected to a capacitor

Image: The FNIRSI LC1020E LCR Meter with test leads connected to a large capacitor, demonstrating the primary and secondary parameter display.

4. මෙහෙයුම් උපදෙස්

4.1 බලය සක්රිය / අක්රිය

ඔබා අල්ලාගෙන සිටින්න බලය උපාංගය සක්‍රිය හෝ අක්‍රිය කිරීමට බොත්තම.

4.2 මූලික සංචාලනය

The LC1020E features several buttons for navigation and setting adjustments:

5. Measurement Modes and Parameters

5.1 Auto Measurement

In ඔටෝ mode, the LC1020E automatically identifies the component type (Resistor, Inductor, or Capacitor) and switches to the appropriate measurement mode, simplifying testing.

FNIRSI LC1020E LCR Meter displaying auto measurement of a capacitor

Image: The FNIRSI LC1020E LCR Meter in 'AUTO' mode, displaying capacitance and dissipation factor for a component, with illustrations of an inductor, resistor, and capacitor.

5.2 Dual Parameter Display

The device simultaneously displays a primary parameter (L, C, R) and a secondary parameter (X, D, Q, θ, ESR), providing a comprehensive analysis of the component under test.

5.3 Test Frequencies and Voltagඊ මට්ටම්

The LC1020E offers multiple test frequencies and RMS voltage levels for versatile measurements:

FNIRSI LC1020E LCR Meter showing selectable test frequencies and RMS levels

Image: The FNIRSI LC1020E LCR Meter display illustrating the selectable test frequencies (100Hz, 120Hz, 1kHz, 10kHz, 100kHz) and RMS voltage levels (0.1V, 0.3V, 0.6V).

5.4 Practical Measurement Scenarios

The LC1020E can be used for various component measurements:

FNIRSI LC1020E LCR Meter demonstrating various measurement scenarios

Image: A collage of five images showing the FNIRSI LC1020E LCR Meter measuring different components: capacitance, resistance, inductance, impedance, and electrolytic capacitors.

6. Smart Sorting & Comparison Mode

The smart sorting feature allows for efficient screening of components based on preset nominal values and tolerance limits. This mode calculates the relative error (%) and provides alerts via sound or LED if components fall outside the specified range.

6.1 Setting Nominal and Tolerance

  1. Navigate to the Sorting/Comparison mode in the menu.
  2. Set the desired nominal value for the component (e.g., 100nF for a capacitor).
  3. Define the tolerance percentagඉ (0.1% සිට 99.9% දක්වා).

6.2 Performing Sorting

Once settings are configured, test components. The device will indicate whether the component meets the criteria (Pass/Fail) and track success/fail counts.

FNIRSI LC1020E LCR Meter in sorting and comparison mode

Image: The FNIRSI LC1020E LCR Meter demonstrating its sorting and comparison mode, showing a component passing the test and another failing, with various components laid out.

7 ක්රමාංකනය

For optimal accuracy, perform open/short calibration periodically or when changing test leads. This compensates for stray capacitance and inductance in the test setup.

7.1 Open Calibration

With no component connected to the test leads, initiate the open calibration process from the menu. This measures and compensates for stray capacitance.

7.2 Short Calibration

Short the test leads together (connect positive to negative) and initiate the short calibration. This measures and compensates for residual inductance and resistance in the leads.

8. FNIRSI LCR-ST1 Tweezer Tester

The FNIRSI LCR-ST1 is a portable LCR/ESR meter in a tweezer format, designed for precise measurement of surface-mount devices (SMD) and other small components. It supports resistance, capacitance, inductance, and diode measurements.

FNIRSI LCR-ST1 Smart Tweezer LCR/ESR Meter

Image: The FNIRSI LCR-ST1 Smart Tweezer LCR/ESR Meter being used to test a component on a circuit board, highlighting its compact design and measurement capabilities.

8.1 LCR-ST1 Measurement Capabilities

FNIRSI LCR-ST1 Smart Tweezer showing auto recognition and parameter display

Image: The FNIRSI LCR-ST1 Smart Tweezer displaying its auto-recognition feature and various parameters like D, Z, Q, X, and ESR, while testing small components.

8.2 Precision Measurement

The LCR-ST1 offers high precision with minimum measurements down to 10mΩ, 1µH, and 1pF, with an accuracy range between 0.5% and 5%.

FNIRSI LCR-ST1 Smart Tweezer displaying precision measurement

Image: A close-up of the FNIRSI LCR-ST1 Smart Tweezer display, showing a precision resistance measurement of 1.942 Ω and a dissipation factor (D) of 458.70.

9. පිරිවිතර

විශේෂාංගයපිරිවිතර
දර්ශන ගණන19,999
Test Frequencies100Hz, 120Hz, 1kHz, 10kHz, 100kHz
පරීක්ෂණ වෙළුමtagඊ මට්ටම්0.1V, 0.3V, 0.6V
අභ්යන්තර නැඹුරුව0.0V, 0.5V
ධාරිතාව පරාසය1pF – 100mF
ප්රතිරෝධක පරාසය10mΩ – 10MΩ
ප්‍රේරක පරාසය1µH – 100H
ප්රතිදාන සම්බාධනය100Ω
මිනුම් වේගයFast (4/s), Medium (2/s), Slow (1/s)
LCR-ST1 Test Frequencies100 Hz, 1 kHz, 10 kHz
LCR-ST1 Test Voltage0.3 Vrms, 0.6 Vrms
LCR-ST1 Resistance Range10 mΩ to 10 MΩ
LCR-ST1 Capacitance Range1 pF to 22 mF
LCR-ST1 Inductance Range1 µH to 10 H

10. දෝශ නිරාකරණය

10.1 සාවද්‍ය කියවීම්

10.2 උපාංගය ක්‍රියාත්මක නොවේ

10.3 සංදර්ශක ගැටළු

11. වගකීම් සහ සහාය

11.1 වගකීම් තොරතුරු

This product typically comes with a standard return policy, allowing for refunds or replacements within 30 days of purchase. Please refer to your purchase documentation for specific warranty terms and conditions.

11.2 පාරිභෝගික සහාය

For technical assistance, troubleshooting, or warranty claims, please contact FNIRSI customer support or visit the official FNIRSI store online. You can find more information and contact details at the FNIRSI Technology Store.